Inlet Air Supply
The inlet air supply enters from the rear of the IVT Oil Mist Generator (IVT). Air is filtered
through an inline filter (1) and enters a distribution manifold (2). The distribution manifold serves
to distribute the air to three separate ball valves (3). The ball valves provide ON-OFF control to,
a) the main oil mist generator head, b) the oil supply pump or c) the auxiliary oil mist generator
head.
The air supply to each device has a ¼ turn ball valve (3) to manually isolate each device for
servicing.
3. Ball Valve
c) Air To Auxiliary Mist Generator
Inlet Air Connection
½ 150 # RF T-304 Flange
1. Air Filter
3. Ball Valve
b) Air To Oil Supply Pump
3. Ball Valve
a) Air To Main Mist Generator Head
2. Air Distribution Manifold
View G-G
View H-H
2. Air Distribution Manifold