As the regulated air pressure increases and exceeds its low alarm set point the regulated air
pressure alarm will clear and the air / oil heater energizes. The air temperature will increase
to the normal heater control setting. If the supply air is cooler than the low temperature
setting, the low air temperature alarm will clear as the air temperature rises above the low
alarm setting.
Once the mist pressure is set, and the mist generator is operating, the mist density reading
will increase and clear the low alarm condition. The mist density output reading increases as
the oil flows through the heater manifold in air / oil heater and increases in temperature. For
additional information regarding adjusting the mist density, see the section titled
CONTROLLING THE MIST.
4. DEPRESS THE “CLEAR” KEY
Once all of the alarms have cleared and normal operating conditions are maintained, use the
"CLEAR" key on the control panel keypad to put the IVT Oil Mist Generator into the normal
operating mode. Press the “CLEAR” key once to clear each of the alarm conditions that were
logged during startup. Once all of the alarm messages have been cleared, press the
“CLEAR” key once more to reset the status lights from fault (red-ON / green-OFF) to normal
(red-OFF / green-ON).
Your LubriMist® Model IVT Oil Mist Generator is now running and in full operation.
NEC Power Switch Location
ATEX Power Switch Location
1
) Turn
ON
The Air
Supply To The Main Oil
Mist Generator Air Block
Valve
3) Use The Main Oil Mist
Generator Air Pressure
Regulator To Set The Mist
Operator Panel
3) Press “MIST PRES” To Monitor The Mist
Pressure As The Air Pressure Regulator Is
Adjusted To Proper Setting.
4) Press “CLEAR” To Clear All Alarm Messages.
Press “CLEAR” To Reset The Unit Status Lights
And Remote Alarm Contacts To Normal
Operation.
2) Place The Three
Position Selector
Switch in the
I
-O-II.
2) Turn
ON
The Main Oil Mist
Generator Power Switch. The
Auxiliary Power Switch Should
Be In The
OFF
Position.