Installation of an air supply block valve in the supply piping is recommended. The valve should be
located just prior to connecting to the IVT air supply connection and be accessible from grade.
The purchaser furnishes the air supply block valve.
IVT Mist
Generator Size
Mist Generating Flow Range
US Units
Metric Units
60 BI
0.60 - 1.80 SCFM
1.02 – 3.06 M
3
/ Hr
213 BI
1.75 – 6.40 SCFM
2.97 – 10.87 M
3
/ Hr
475 BI
2.48 – 14.30 SCFM
4.21 – 24.30 M
3
/ Hr
933 BI
5.70 – 28.0 SCFM
9.68 – 47.57 M
3
/ Hr
IVT Mist
Generator Size
Minimum Recommended Air Supply Capacity
∴
US Units
Metric Units
60 BI
5 SCFM @ 65 PSIG
8.5 M
3
/HR @4.5 BAR
213 BI
10 SCFM @ 65 PSIG
17 M
3
/HR @4.5 BAR
475 BI
18 SCFM @ 65 PSIG
31 M
3
/HR @4.5 BAR
933 BI
32 SCFM @ 65 PSIG
55 M
3
/HR @4.5 BAR
∴
Includes the airflow requirement needed to operate the oil transfer pump.
MAXIMUM AIR SUPPLY PRESSURE IS 150
PSI / 10.3 BAR. DO NOT EXCEED MAXIMUM
INLET AIR SUPPLY PRESSURE
WARNING
INLET AIR SUPPLY MUST BE EQUIPPED
WITH A SAFETY RELIEF VALVE FOR OVER
PRESSURE PROTECTION
WARNING