![RelaDyne LubriMist IVT Installation And Operating Manual Download Page 186](http://html1.mh-extra.com/html/reladyne/lubrimist-ivt/lubrimist-ivt_installation-and-operating-manual_1435628186.webp)
LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page
186 of
256
Voltage Panel Wiring Diagram -115 VAC Supply Voltage / IVT – ATEX Construction
II-0-I
3
1
2
43
31 23
I= MAIN UNIT
0= OFF
II= AUXILIARY UNIT
T
X-
R
X+
R
X-
TX
+
10 6
1
2
3
11
SELECTOR SWITCH
AC VOLTAGE COMPONENTS
SUPPLY POWER
USER CONNECTION
2.5MM
44
32
24
REMOTE ALARM
CONTACTS
CONNECTION
N
.C.
R
X-
R
X+
C
OM
N
.O.
INSTRUMENT
GROUND TERMINAL
12
TB-1
TB-2
T
X-
TX
+
DC VOLTAGE COMPONENTS
SERIAL DATA PORT
RS-422/485
RX-
RX+
TX-
TX+
DO#4 +
DO#4 -
TX+
RX+
TX-
RX-
R
X-
R
X+
D
O
#
4 -
TX
+
T
X-
D
O#
4
+
TO DO#4
FOR DEMISTING MOTOR INTERLOCK
D
O#
4
+
D
O
#
4
-
TB8
8
11
10
9
TB5
3-
3+
SOLID STATE
TB9/SOLID STATE CONTROLLER
+24V
GND
1
13
2
17
3 16
10
4
15
14
8
12
13
9
HEATER
(OPTIONAL EQUIP)
AIR PREHEATER
LOCAL UNIT
STATUS
LIGHTS
6
H-1
5
7
H-3
15
14
16
4
9
17
AIR/OIL
G
R
XL-1
XL-2
MAIN UNIT AC POWER ELECTRICAL PANEL
SSR-1
CONTROLLER
10.5mA @ 5 VDC
MAXIMUM SWITCHED CURRENT
2
3
SSR-1 SSR-2
BU
BU
1
6
4
7
SWITCH
HEATER
AIR/OIL
LOW
PRESSURE
6
5
PSL
3
H-2
8
7
1 4
EC-2
SEE DETAIL
AUXILIARY UNIT
ELECTRONIC
CONTROLLER