background image

N-Tron

®

 Series 700/7000 Managed Industrial Ethernet Switch Hardware Manual - Volume I

1-33

Product Overview

Revised 2019-08-22

Ordering Guide

Drawing No. LP0988

 

1.13.6

 

7018FX2

Part Number

Description

7018FX2-XX-VV

14 10/100Base-TX Ports, Two Multimode 100BaseFX Fiber Optic Ports, Two 

Optional Gigabit SFP Ports Managed Industrial Ethernet Switch

7018FXE2-XX-YY-VV

14 10/100Base-TX Ports, Two Singlemode 100BaseFX Fiber Optic Ports, Two 

Optional Gigabit SFP Ports Managed Industrial Ethernet Switch

NTSFP-TX

1000BaseT copper SFP (Mini-GBIC) Transceiver (RJ45 connector)

NTSFP-SX

1000BaseSX multimode fiber SFP (Mini-GBIC) Transceiver (LC style connector)

NTSFP-LX-ZZ

1000BaseLX singlemode fiber SFP (Mini-GBIC) Transceiver (LC style connector)

700-PM

Panel Mount Kit

NTPS-24-1.3

Power Supply 1.3 Amp @ 24 VDC

NTPS-48-2

Power Supply 2 Amp @ 48 VDC (For use with -HV model only)

URMK

19” Universal Rack Mount Kit

Where XX = ST or SC connector

Where YY = 15, 40, or 80 for Singlemode, Blank for Multimode
Where E = Singlemode, and Blank Otherwise
Where ZZ = 10, 40, or 80 GB Singlemode
                     If SFP Transceiver is not specified at the time of purchase, slots will remain blank with covers.
Where VV = HV for High Voltage, Blank for standard voltage

Summary of Contents for 7018FX-HV

Page 1: ...N Tron Series 700 7000 Models Volume I Hardware Manual August 2019 Managed Industrial Ethernet Switches LP0988 Revision B...

Page 2: ...are trademarks of Red Lion Controls Inc All other company and product names are trademarks of their respective owners Red Lion Controls Inc 20 Willow Springs Circle York PA 17406 CONTACT INFORMATION I...

Page 3: ...eral Safety Cautions and Warnings Pr cautions et Avertissements de S curit G n rale vi Electrical Safety Warnings Avertissements de S curit lectrique vii Environmental Safety Cautions and Warnings S c...

Page 4: ...cifications 1 19 1 8 3 716M12 Dimensions 1 20 1 9 7018TX 1 21 1 9 1 Features and Benefits 1 21 1 9 2 7018TX Specifications 1 22 1 9 3 7018TX Dimensions 1 23 1 10 7018FX2 1 24 1 10 1 Features and Benef...

Page 5: ...1 708TX 708FX2 716TX 716FX2 7018TX and 7018FX2 Models 2 42 2 4 2 708M12 and 716M12 Models 2 43 2 5 Grounding the Switch 2 43 2 5 1 Grounding 708TX 708FX2 716TX 716FX2 7018TX and 7018FX2 Models 2 44 2...

Page 6: ...e local regulations Part 15 of the Federal Communications Commission FCC A Rules Interference Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class...

Page 7: ...ux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op rati...

Page 8: ...nformation can be obtained by contacting the local sales representative or Red Lion through the contact numbers and or e mail addresses listed on the inside of the front cover Cautions and Warnings Mi...

Page 9: ...s autorit s ayant comp tence Class A device Broad casting and communication equipments for office work This equipment is office use Class A electromagnetic wave suitability equipment and seller or use...

Page 10: ...ust be provided from the same Class 2 source AVERTISSEMENT Mod les 708M12 et 716M12 pour applications redondantes les deux entr es doivent tre fournis partir de la m me source de classe 2 WARNING Do n...

Page 11: ...re moins que la r gion est connue pour tre l abri de des concentrations de substances inflammables Le marquage doit tre affich e dans un endroit bien en vue sur l enceinte WARNING Explosion Hazard Sub...

Page 12: ...able before removing any enclosure panel AVERTISSEMENT D brancher le c ble d alimentation avant de retirer tout panneau de bo tier WARNING Use 60 75 C rated Copper wire for models 708TX 708FX E 2 and...

Page 13: ...x nA nC IIC Gc DEMKO 03 ATEX 0316686U x x x x x x II 3 G Ex nA IIC Gc DEMKO 03 ATEX 0316686U x x TUV GS EN 60950 1 AfPS GS 2014 x x x x x x EMI ANSI C63 4 FCC 47 CFR Part 15 Subpart B Class A ICES 003...

Page 14: ...16TX HV 716FX2 716FX2 HV 716M12 716M12 HV 7018TX 7018TX HV 7018FX2 7018FX2 HV Other ABS PDA and Type Approval for Shipboard Applications x x x x EMC Directive 2014 30 EU x x x x x x x x x x x x x x Lo...

Page 15: ...ns and media types with 10 100 copper as well as Fast Ethernet and Gigabit fiber options 1 1 2 Performance 700 7000 managed switches provide uncompromising performance in harsh environments Network ma...

Page 16: ...re 10 100 TX RJ45 Copper Ports 100 FX Ports SFPs Redundant Power Input HV Option Power Input 708TX 8 DIN Rail 40 C to 85 C 8 10 30 VDC 708FX2 8 DIN Rail 40 C to 85 C 6 2 10 30 VDC 708M12 8 Bulkhead DI...

Page 17: ...er Inputs 40 C to 85 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking...

Page 18: ...24 VDC 20 5 24 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Sh...

Page 19: ...Industrial Ethernet Switch Hardware Manual Volume I 1 5 Product Overview Revised 2019 08 22 708TX Drawing No LP0988 1 3 3 708TX Dimensions All specifications are subject to change Consult the company...

Page 20: ...T or SC Redundant 10 to 30 VDC Power Inputs 40 C to 85 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol...

Page 21: ...ental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms...

Page 22: ...view Drawing No LP0988 708FX2 1 8 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I 1 4 3 708FX2 Dimensions All specifications are subject to change Consult the compan...

Page 23: ...Rated for protection against temporary immersion in water IP67 Rated Hardened Metal Enclosure Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trun...

Page 24: ...e Storage Temperature Operating Humidity Operating Altitude 40 C to 80 C 40 C to 85 C 5 to 100 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10 ms 50g 5 200Hz Triaxial Un...

Page 25: ...Industrial Ethernet Switch Hardware Manual Volume I 1 11 Product Overview Revised 2019 08 22 708M12 Drawing No LP0988 1 5 3 708M12 Dimensions All specifications are subject to change Consult the compa...

Page 26: ...40 C to 70 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable s...

Page 27: ...VDC Regulated 160 mA 124 VDC 67 7 124 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft...

Page 28: ...rview Drawing No LP0988 716TX 1 14 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I 1 6 3 716TX Dimensions All specifications are subject to change Consult the compan...

Page 29: ...ant 10 to 30 VDC Power Inputs 40 C to 70 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with ot...

Page 30: ...67 7 124 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vi...

Page 31: ...Industrial Ethernet Switch Hardware Manual Volume I 1 17 Product Overview Revised 2019 08 22 716FX2 Drawing No LP0988 1 7 3 716FX2 Dimensions All specifications are subject to change Consult the compa...

Page 32: ...rection IP66 Rated for protection against high pressure jets of water from any direction IP67 Rated for protection against temporary immersion in water IP67 Rated Hardened Metal Enclosure Autosensing...

Page 33: ...ating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 85 C 40 C to 80 C HV 40 C to 85 C 5 to 100 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 20...

Page 34: ...view Drawing No LP0988 716M12 1 20 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I 1 8 3 716M12 Dimensions All specifications are subject to change Consult the compa...

Page 35: ...5 style Redundant 10 to 30 VDC Power Inputs Keeps network running in the event of a power supply failure HV High Voltage Option 40 160VDC 40 C to 70 C operating temperature ESD and Surge Protection Di...

Page 36: ...Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit m...

Page 37: ...Industrial Ethernet Switch Hardware Manual Volume I 1 23 Product Overview Revised 2019 08 22 7018TX Drawing No LP0988 1 9 3 7018TX Dimensions All specifications are subject to change Consult the compa...

Page 38: ...0 to 30 VDC Power Inputs 40 C to 70 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N...

Page 39: ...ge Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must b...

Page 40: ...ew Drawing No LP0988 7018FX2 1 26 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I 1 10 3 7018FX2 Dimensions All specifications are subject to change Consult the comp...

Page 41: ...0 nm 1310 nm 1550 nm Multimode Fiber Optic Cable Singlemode Fiber Optic Cable 1 11 2 Gigabit Fiber Transceiver SFP Characteristics Fiber Length 550 m 50 125 m 275 m 62 5 125 m 10 km 40 km 80 km TX Pow...

Page 42: ...indicates link status and the ACT LED indicates activity The table below describes the operating modes LED Color Description Green Power is On with no active faults Red Power is On and an active fault...

Page 43: ...sal Rack Mount Kit 1 13 2 708FX2 708FXE2 Part Number Description 708FX2 XX Six Port 10 100Base TX Ports Two Multimode 100BaseFX Fiber Optic Ports Managed Industrial Ethernet Switch 708FXE2 XX YY Six P...

Page 44: ...anual Volume I 1 13 3 716TX Part Number Description 716TX VV 16 Port 10 100Base TX Ports Managed Industrial Ethernet Switch 700 PM Panel Mount Kit NTPS 24 1 3 Power Supply 1 3 Amp 24 VDC NTPS 48 2 Pow...

Page 45: ...ustrial Ethernet Switch 716FXE2 XX YY VV 14 Port 10 100Base TX Ports Two Singlemode 100BaseFX Fiber Optic Ports Managed Industrial Ethernet Switch 700 PM Panel Mount Kit NTPS 24 1 3 Power Supply 1 3 A...

Page 46: ...sceiver RJ45 connector NTSFP SX 1000BaseSX multimode fiber SFP Mini GBIC Transceiver LC style connector NTSFP LX ZZ 1000BaseLX singlemode fiber SFP Mini GBIC Transceiver LC style connector 700 PM Pane...

Page 47: ...TX 1000BaseT copper SFP Mini GBIC Transceiver RJ45 connector NTSFP SX 1000BaseSX multimode fiber SFP Mini GBIC Transceiver LC style connector NTSFP LX ZZ 1000BaseLX singlemode fiber SFP Mini GBIC Tra...

Page 48: ...DIN Rail kit CAT5E M12 M12 X Straight M12 to Straight M12 Shielded CAT5E M12 RJ45 X Straight M12 to Straight RJ45 Shielded CAT5E M12 X Straight M12 to Bare End Shielded CAT5E RM12 M12 X 90 M12 to Str...

Page 49: ...X Straight M12 to Straight M12 Shielded CAT5E M12 RJ45 X Straight M12 to Straight RJ45 Shielded CAT5E M12 X Straight M12 to Bare End Shielded CAT5E RM12 M12 X 90 M12 to Straight M12 Shielded CAT5E RM...

Page 50: ...Revised 2019 08 22 Product Overview Drawing No LP0988 Ordering Guide 1 36 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I This Page Intentionally Left Blank...

Page 51: ...product temperature testing shall be considered 5 The end user shall provide bonding means as necessary All bonding equipment components shall be evaluated according to EN 60079 15 2010 and covered by...

Page 52: ...ip on the back of the switch to the rail at an upward angle 2 Then gently rotate the front of the switch downward towards the panel 3 Push the bottom of the switch towards the rail until it locks into...

Page 53: ...om of the unit to allow proper ventilation 2 3 2 1 Vertical Mounting 716TX 716FX2 7018TX and 7018FX2 Install the switch to standard 35mm DIN Rail as shown in the diagram above Note When mounting the s...

Page 54: ...apply upward force on the screwdriver to release the DIN Rail clip 6 With the DIN Rail clip latching mechanism released continue to rotate the switch upward and away from the panel 7 Once the switch...

Page 55: ...l M12DRC or M12DRC ISO DIN Rail kit to the back of the switch 2 Place the bottom edge of the bracket on the back of the unit against the DIN Rail bottom edge at a downward angle 3 Then gently rotate t...

Page 56: ...ut plug back into the power input header This is the power disconnect device that must be removed before performing any kind of service or maintenance on the device 4 Tightening torque for the termina...

Page 57: ...he switch when required The best noise immunity and emissions i e CE are obtained when the Red Lion switch chassis is connected to earth ground via a drain wire 20 gauge minimum size wire Some Red Lio...

Page 58: ...que Avant de mettre sous tension le commutateur de mise la terre vous utilisez un voltm tre pour v rifier qu il n y a pas de diff rence de tension entre l alimentation de la borne de sortie n gative e...

Page 59: ...The RX port on the FX FXE versions should be connected to the TX port of the far end station For 10 100 Base TX ports plug a Category 5E twisted pair cable into the RJ45 connector Connect the other en...

Page 60: ...y recommended to only connect the shield at one end to prevent ground loops and interference with low level signals i e thermocouples RTD etc CAT5e cables manufactured to EIA 568A or 568B specificatio...

Page 61: ...b D female connector for the PC end and a 9 pin male sub D connector for the 700 7000 switch model end The following table shows the pin out and the connections for both types of cable 2 6 3 Connectin...

Page 62: ...user does not follow one of these two color code standards then the performance and maximum cable distance will be reduced significantly and may prevent the switch from establishing a link Warning Av...

Page 63: ...oting the device is comprised of a few basic steps as provided below If these do not resolve the issue then contact Red Lion as per the guidance provided in Service Information on page 53 1 Make sure...

Page 64: ...Switch Hardware Manual Volume I 2 Make sure you are supplying sufficient current for the version chosen Note The Inrush current will exceed the steady state current by 2X 3 Verify that Link LEDs are O...

Page 65: ...The DHCP Client is enabled by default with the 192 168 1 201 as the fallback address 2 The following login screen will appear 3 For the User Name enter admin all lowercase 4 For the password enter adm...

Page 66: ...Accessing the Web Software Interface Drawing No LP0988 3 52 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I Please consult the 700 7000 Software Manual LP0985 for co...

Page 67: ...ty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This help...

Page 68: ...RMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law...

Page 69: ...Revised 2019 08 22 Limited Warranty Drawing No LP0988 3 55 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume I...

Page 70: ...N Tron Series 700 7000 Models Volume II Hardware Manual August 2019 Managed Industrial Ethernet Switches LP0988 Revision B...

Page 71: ...egistered trademarks of Red Lion Controls Inc All other company and product names are trademarks of their respective owners Red Lion Controls Inc 20 Willow Springs Circle York PA 17406 CONTACT INFORMA...

Page 72: ...s Avertissements de S curit lectrique vii Environmental Safety Cautions and Warnings S curit Environnementale Mises en Garde et Avertissements viii Hazardous Location Warnings Les Avertissements d Emp...

Page 73: ...X Specifications 1 29 1 10 3 7026TX Dimensions 1 30 1 11 7506GX2 1 31 1 11 1 Features and Benefits 1 31 1 11 2 7506GX2 Specifications 1 32 1 11 3 7506GX2 Dimensions 1 33 1 12 7900 1 34 1 12 1 Features...

Page 74: ...anel Mounting 7026TX Model 2 58 2 4 Connect Power Source 2 59 2 4 1 709FX 710FX2 711FX3 712FX4 714FX6 7010TX and 7012FX2 Models 2 59 2 4 2 7026TX 2 60 2 4 3 7026TX AC 2 60 2 4 4 7506GX2 2 61 2 4 5 790...

Page 75: ...cable local regulations Part 15 of the Federal Communications Commission FCC A Rules Interference Every effort has been made to ensure that this equipment is designed to comply with the limits for a C...

Page 76: ...ux conditions suivantes 1 ce dispositif peut ne pas causer l interf rence nocive et 2 ce dispositif doit accepter n importe quelle interf rence re ue y compris l interf rence qui peut causer l op rati...

Page 77: ...can be obtained by contacting the local sales representative or Red Lion through the contact numbers and or e mail addresses listed on the inside of the front cover Cautions and Warnings Mises en Gard...

Page 78: ...ent or cabling during periods of lightning activity AVERTISSEMENT Ne jamais installer ou travailler sur quipement lectrique ou de c blage pendant les p riodes d activit de la foudre CAUTION Do not per...

Page 79: ...tretien de l quipement sans avoir pr alablement d branch le connecteur d alimentation WARNING Do not operate the unit with any cover removed as this could create a shock or fire hazard AVERTISSEMENT N...

Page 80: ...brancher ou d brancher les connexions lorsque le circuit est sous tension sauf si la zone est connue pour tre non dangereux WARNING Explosion Hazard Do not remove or replace the Ethernet or fiber opti...

Page 81: ...es 712FX4 40 80 mod les 714FX6 40 80 mod les 7010TX et en option NTSFP LX 40 et 80 les mod les 7012FX2 40 80 et en option NTSFP LX 40 et 80 7026TX mod les et en option NTSFP LX 40 et 80 les mod les 75...

Page 82: ...C 47 CFR Part 15 Subpart B Class A ICES 003 x x x x x x x x x x x x x x x EN 61000 6 4 Emissions x x x x x x x x x x x x x x x EN 61000 3 2 3 Emissions x EN 55022 Emissions x EMC EN 61000 6 2 Immunity...

Page 83: ...11FX3 711FX3 HV 712FX4 712FX4 HV 714FX6 7010TX 7012FX2 7012FX2 HV 7026TX 7506GX2 7900 Designed to comply with NEMA TS1 TS2 Traffic Control x x x x x x x x x x x x x x x ABS PDA and Type Approval for S...

Page 84: ...ly managed Ethernet switch models offer a wide array of port configurations and media types with 10 100 copper as well as Fast Ethernet and Gigabit fiber options For maximum flexibility the models are...

Page 85: ...put 709FX 9 DIN Rail 40 C to 70 C 8 1 10 49 VDC 43 300 VDC 710FX2 10 DIN Rail 40 C to 70 C 8 2 10 49 VDC 43 300 VDC 711FX3 11 DIN Rail 40 C to 70 C 8 3 10 49 VDC 43 300 VDC 712FX4 12 DIN Rail 40 C to...

Page 86: ...r Ports One 100BaseFX E Port Redundant 10 to 49 VDC Power Inputs 40 C to 70 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid S...

Page 87: ...34 124 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibra...

Page 88: ...Industrial Ethernet Switch Hardware Manual Volume II 1 5 Product Overview Revised 2019 08 22 709FX Drawing No LP0988 1 3 3 709FX Dimensions All specifications are subject to change Consult the compan...

Page 89: ...iew Drawing No LP0988 709FX 1 6 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 3 4 709FX HV Dimensions All specifications are subject to change Consult the compa...

Page 90: ...puts 40 C to 70 C operating temperature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capab...

Page 91: ...41 124 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibr...

Page 92: ...Industrial Ethernet Switch Hardware Manual Volume II 1 9 Product Overview Revised 2019 08 22 710FX2 Drawing No LP0988 1 4 3 710FX2 Dimensions All specifications are subject to change Consult the compa...

Page 93: ...ew Drawing No LP0988 710FX2 1 10 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 4 4 710FX2 HV Dimensions All specifications are subject to change Consult the com...

Page 94: ...ion Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store Forward Technology Plug and...

Page 95: ...45 124 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibra...

Page 96: ...ndustrial Ethernet Switch Hardware Manual Volume II 1 13 Product Overview Revised 2019 08 22 711FX3 Drawing No LP0988 1 5 3 711FX3 Dimensions All specifications are subject to change Consult the compa...

Page 97: ...ew Drawing No LP0988 711FX3 1 14 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 5 4 711FX3 HV Dimensions All specifications are subject to change Consult the com...

Page 98: ...on Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store Forward Technology Plug and P...

Page 99: ...4 VDC Environmental Operating Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration...

Page 100: ...ndustrial Ethernet Switch Hardware Manual Volume II 1 17 Product Overview Revised 2019 08 22 712FX4 Drawing No LP0988 1 6 3 712FX4 Dimensions All specifications are subject to change Consult the compa...

Page 101: ...ew Drawing No LP0988 712FX4 1 18 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 6 4 712FX4 HV Dimensions All specifications are subject to change Consult the com...

Page 102: ...ge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store Forward Technology...

Page 103: ...ting Temperature Storage Temperature Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10 ms 50g 5 200...

Page 104: ...ndustrial Ethernet Switch Hardware Manual Volume II 1 21 Product Overview Revised 2019 08 22 714FX6 Drawing No LP0988 1 7 3 714FX6 Dimensions All specifications are subject to change Consult the compa...

Page 105: ...and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store Forward Te...

Page 106: ...g Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10 ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these level...

Page 107: ...iew Drawing No LP0988 7010TX 1 24 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 8 3 7010TX Dimensions All specifications are subject to change Consult the compa...

Page 108: ...ection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store Forward Technology Plug a...

Page 109: ...Operating Humidity Operating Altitude 40 C to 70 C 40 C to 85 C 5 to 95 non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10 ms 50g 5 200Hz Triaxial Unit must be bulkhead mou...

Page 110: ...dustrial Ethernet Switch Hardware Manual Volume II 1 27 Product Overview Revised 2019 08 22 7012FX2 Drawing No LP0988 1 9 3 7012FX2 Dimensions All specifications are subject to change Consult the comp...

Page 111: ...perature ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Stor...

Page 112: ...non condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10 ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100BaseTX 24 RJ45 copper port...

Page 113: ...iew Drawing No LP0988 7026TX 1 30 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 10 3 7026TX Dimensions All specifications are subject to change Consult the comp...

Page 114: ...n Diodes on all Ports Autosensing 10 100 1000BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store Forward Technology Plug a...

Page 115: ...n condensing 0 to 10 000 ft Shock and Vibration Shock Vibration Note 200g 10ms 50g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100 1000BaseT X Four RJ45 copper...

Page 116: ...dustrial Ethernet Switch Hardware Manual Volume II 1 33 Product Overview Revised 2019 08 22 7506GX2 Drawing No LP0988 1 11 3 7506GX2 Dimensions All specifications are subject to change Consult the com...

Page 117: ...ure ESD and Surge Protection Diodes on all Ports Autosensing 10 100BaseTX Duplex and MDIX Offers Rapid Spanning Tree Protocol Trunk with other N Tron trunking capable switches over two ports Store For...

Page 118: ...on Note 50g 10ms 30g 5 200Hz Triaxial Unit must be bulkhead mounted to achieve these levels Connectors 10 100BaseTX Up to 24 RJ45 copper ports 100BaseFX Up to 16 SC or ST duplex fiber ports Optional S...

Page 119: ...rview Drawing No LP0988 7900 1 36 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 12 3 7900 Dimensions All specifications are subject to change Consult the compan...

Page 120: ...el Mount Their are five optional panel mounts available for use with the switches CPMA 1 CPMA 2 1000 PM 7026TX PMK 9000 PM 1 13 1 Panel Mount Application Panel Mount Application Switch Model CPMA 1 CP...

Page 121: ...sed 2019 08 22 Product Overview Drawing No LP0988 Optional Panel Mount 1 38 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 13 2 Compact Panel Mount CPMA 1 Dimens...

Page 122: ...on Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 39 Product Overview Revised 2019 08 22 Optional Panel Mount Drawing No LP0988 1 13 3 Compact Panel Mount CPMA 2 Dimens...

Page 123: ...evised 2019 08 22 Product Overview Drawing No LP0988 Optional Panel Mount 1 40 N Tron Series 700 7000 Managed Industrial Ethernet Switch Hardware Manual Volume II 1 13 4 Panel Mount 9000 PM Dimensions...

Page 124: ...0 nm 1310 nm 1550 nm Multimode Fiber Optic Cable Singlemode Fiber Optic Cable 1 14 2 Gigabit Fiber Transceiver SFP Characteristics Fiber Length 550 m 50 125 m 275 m 62 5 125 m 10 km 40 km 80 km TX Pow...

Page 125: ...ts GB ports have two LEDs arrows located on each connector The bottom LED right pointing arrow indicates link LNK status and the top LED left pointing arrow indicates activity ACT The table below desc...

Page 126: ...t eight 10 100Base TX 1 100BaseFX Fiber Uplink Managed Industrial Ethernet Switch singlemode DIN Rail NTCD 128 Optional Configuration Card for backup restore NTPS 24 1 3 Power Supply 1 3 Amp 24 VDC NT...

Page 127: ...100Base TX 2 100BaseFX Fiber Uplink Managed Industrial Ethernet Switch singlemode DIN Rail NTCD 128 Optional Configuration Card for backup restore NTPS 24 1 3 Power Supply 1 3 Amp 24 VDC NTPS 48 2 Pow...

Page 128: ...100Base TX 3 100BaseFX Fiber Uplink Managed Industrial Ethernet Switch singlemode DIN Rail NTCD 128 Optional Configuration Card for backup restore NTPS 24 1 3 Power Supply 1 3 Amp 24 VDC NTPS 48 2 Pow...

Page 129: ...12FXE4 XX YY VV 12 Port eight 10 100Base TX 4 100BaseFX Fiber Uplink Managed Industrial Ethernet Switch singlemode DIN Rail NTCD 128 Optional Configuration Card for backup restore NTPS 24 1 3 Power Su...

Page 130: ...naged Industrial Ethernet Switch DIN Rail 714FXE6 XX YY 14 Port eight 10 100Base TX 6 100BaseFX Fiber Uplink Managed Industrial Ethernet Switch singlemode DIN Rail NTCD 128 Optional Configuration Card...

Page 131: ...per SFP Mini GBIC Transceiver RJ45 connector NTSFP SX 1000BaseSX multimode fiber SFP Mini GBIC Transceiver LC style connector NTSFP LX ZZ 1000BaseLX singlemode fiber SFP Mini GBIC Transceiver LC style...

Page 132: ...copper SFP Mini GBIC Transceiver RJ45 connector NTSFP SX 1000BaseSX multimode fiber SFP Mini GBIC Transceiver LC style connector NTSFP LX ZZ 1000BaseLX singlemode fiber SFP Mini GBIC Transceiver LC st...

Page 133: ...nsion ports Managed Industrial Ethernet Switch 19 rackmount 90 264 VAC 90 300 VDC power input NTSFP TX 1000BaseT copper SFP Mini GBIC Transceiver RJ45 connector NTSFP SX 1000BaseSX multimode fiber SFP...

Page 134: ...LX 10 Four 10 100 1000Base T X two SFP ports with two NTSFP LX 10 singlemode modules installed Managed Industrial Ethernet Switch DIN Rail NTSFP TX 1000BaseT copper SFP Mini GBIC Transceiver RJ45 con...

Page 135: ...Four 100Base FX singlemode fiber port slide in module NTSFP TX 1000BaseT copper SFP Mini GBIC Transceiver RJ45 connector NTSFP SX 1000BaseSX multimode fiber SFP Mini GBIC Transceiver LC style connect...

Page 136: ...anel mount option will work with your switch The proper clearance should be observed on the sides back top and bottom to allow proper ventilation Also observe the proper cable bend radius for the fron...

Page 137: ...any communications cables to the switch 6 Install the power and ground wires 7 Apply power to the power supply 2 3 2 DIN Rail Removal Instructions 709FX 710FX2 711FX3 712FX4 714FX6 7010TX 7012FX2 and...

Page 138: ...ching mechanism released continue to rotate the switch upward and away from the panel 7 Once the switch has been rotated upward remove the screwdriver 8 Carefully lift the switch upward and away from...

Page 139: ...t align the mounting brackets slots with the rack mounting holes 2 Insert a mounting screw into the rack mounting hole through the right or left mounting bracket and hand tighten Repeat on the other s...

Page 140: ...the power supply 2 3 5 Rack and Panel Mounting Instructions for 7026TX Model The 7026TX model is preconfigured with standard rack mount brackets used to mount the unit to standard 19 racks As an alte...

Page 141: ...align the mounting brackets slots with the desired installation location on the flat surface 3 Mark the mounting brackets slot locations 4 Drill a hole at each marked location 5 While supporting the...

Page 142: ...e input plug back into the power input header This is the power disconnect device that must be removed before performing any kind of service or maintenance on the device 4 Tightening torque for the te...

Page 143: ...age input plug from the power input header 2 Install the DC power cables into the plug observing polarity 3 Plug the voltage input plug back into the power input header This is the power disconnect de...

Page 144: ...put 1 Unscrew and remove the AC voltage input plug from the power input header 2 Install the AC power cables into the plug observing polarity 3 Plug the voltage input plug back into the power input he...

Page 145: ...header 2 Install the DC power cables into the plug observing polarity 3 Plug the voltage input plug back into the power input header This is the power disconnect device that must be removed before per...

Page 146: ...if isolation is required 2 5 1 Grounding 709FX 710FX2 711FX3 712FX4 714FX6 7010TX and 7012FX2 Models Both V legs of the power input connector are connected to chassis internally on the PCB Connecting...

Page 147: ...e required for use with Red Lion Switches In the event all CAT5E patch cable distances are small i e All Ethernet devices are located in the same local cabinet and or referenced to the same earth grou...

Page 148: ...in Note Recommend using a 6 32 x 1 4 Phillips pan head zinc screw Failure to do so may cause irreversible damage to the internal components of the switch Note Before applying power to the grounded sw...

Page 149: ...he switch Note Before applying power to the grounded switch you should use a volt meter to verify there is no voltage difference between the power supply s negative output terminal and the switch chas...

Page 150: ...y prevent the switch from establishing a link Warning Avertissement Creating a network loop without employing a network path protocol such as N Ring N Link or RSTP is an illegal operation that can cre...

Page 151: ...t or crossover cable with two 8 pin RJ45 connectors on each end To visually confirm that Ethernet cabling was done properly check the LED indication on the Ethernet port of the unit The link LED shoul...

Page 152: ...ace 7900 The 7900 switch models provides an EIA 232 interface accessed via a DB9 pin female connector labeled COM on the unit This is used to access the Command Line Interface CLI The pin outs are sho...

Page 153: ...ommand Line Interpreter CLI Each switch USB port location is provided below 2 6 5 1 USB Cable Connect the USB port of your PC and the Switch using a standard USB cable This requires a cable with a Typ...

Page 154: ...y without the need for a computer or software Each switch NTCD insertion point location is provided below The SD and USB connectors are for temporary connection only 2 8 1 NTCD 128 SD Card Configurati...

Page 155: ...panel or module that you are replacing 3 Using both hands pull on both thumb screws to slide the filler panel or module you are replacing 4 Align the new module such that it slides on the rails and f...

Page 156: ...s to slide the CPU module out of the chassis 4 Align the new CPU Module such that it slides on the rails and firmly push it into the unit 5 Screw both thumb screws down till they are finger tight 6 Re...

Page 157: ...The DHCP Client is enabled by default with the 192 168 1 201 as the fallback address 2 The following login screen will appear 3 For the User Name enter admin all lowercase 4 For the password enter ad...

Page 158: ...00 Managed Industrial Ethernet Switch Hardware Manual Volume II 3 75 Accessing the Web Software Interface Revised 2019 08 22 Drawing No LP0988 Please consult the 700 7000 Software Manual LP0985 for co...

Page 159: ...ty Please supply us with as many details about the problem as you can The information you supply will be written on the RO form and supplied to the repair department before your unit arrives This help...

Page 160: ...ORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal la...

Reviews: