Revised 2019-08-22
Product Overview
Drawing No. LP0988
7012FX2
1-26
N-Tron
®
Series 700/7000 Managed Industrial Ethernet Switch Hardware Manual - Volume II
1.9.2
7012FX2
Specifications
Refer to
“100 MB Fiber Transceiver Characteristics”
Refer to
“Gigabit Fiber Transceiver (SFP) Characteristics”
* High voltage option
Mechanical
Height
Width
Depth
Weight
Mount
4.3" (10.9 cm)
3.1" (7.9 cm)
4.6" (11.7 cm)
1.65 lbs (0.75 kg)
35mm DIN-Rail
Power Input
Input Voltage
Steady Input Current
BTU/hr
10-49 VDC (Regulated)
525 mA @ 24 VDC
44 @ 24 VDC
43-300 VDC (Regulated)*
140 mA @ 124 VDC*
60 @ 124 VDC*
Environmental
Operating
Temperature
Storage Temperature Operating Humidity
Operating Altitude
-40 °C to 70 °C
-40 °C to 85 °C
5% to 95% (non condensing)
0 to 10,000 ft.
Shock and Vibration
Shock
Vibration
Note
200g @ 10 ms
50g, 5-200Hz, Triaxial
Unit must be bulkhead mounted to achieve these
levels.
Connectors
10/100BaseTX: Eight RJ45 copper ports
100BaseFX: Two SC or ST duplex fiber ports
Optional SFP Ports: 1000BaseT: Up to two RJ45 gigabit copper ports or,
1000BaseSX/LX: Up to two LC duplex gigabit fiber ports
Recommended Minimum Wiring Clearance
Top
1" (2.54 cm)
Front
4” (10.16 cm)
Bottom
1" (2.54 cm)
Network Media
10BaseT
100BaseTX
1000BaseT
100BaseFX,
1000BaseSX
100BaseFXE,
1000BaseLX
≥CAT3 Cable
≥CAT5 Cable
≥CAT5E Cable
Multimode:
50-62.5/125µm
Singlemode:
7-10/125µm
Switch Properties
Number of MAC Addresses
Aging Time
Latency (Typical)
Switching Method
8,000
Programmable
2.6 µs
Store & Forward