Series 700/7000 Managed Industrial Ethernet Switch Hardware Manual - Volume II
2-53
Hardware Installation
Revised 2019-08-22
Unpacking
Drawing No. LP0988
Chapter
2
Hardware
Installation
2.1
Unpacking
Remove all the equipment from the packaging and store the packaging in a safe place. File any damage claims
with the carrier.
Make certain the N-Tron
®
Series 700/7000 Ethernet Switch package contains the following items:
1.
700/7000 switch
2.
Product CD
2.2
Mounting
the
Switch
Red Lion offers several panel mount options which may be used to securely mount the 700/7000 models to a panel
or other flat surface. Refer to section 1.13 to determine which panel mount option will work with your switch.
The proper clearance should be observed on the sides, back, top and bottom to allow proper ventilation. Also,
observe the proper cable bend radius for the front and top side of the unit.
2.3.1
DIN
‐
Rail
Mounting
Instructions
709FX,
710FX2,
711FX3,
712FX4,
714FX6,
7010TX,
7012FX2,
7506GX2,
and
7900
Models
Install the unit on a standard 35mm Din-Rail. Recess the unit to allow at least 3” of horizontal clearance for copper
cable bend radius. Recess the unit to allow at least 5” of horizontal clearance for fiber cable bend radius. There
should be at least 3” of clearance on both the top and bottom of the unit to allow proper ventilation.
2.3.1.1 Mounting
Install the switch to standard 35mm DIN-Rail as shown in the diagram above.
1.
Hook the top of the DIN-Rail clip on the back of the switch to the rail at an upward angle.