Connect Power Source
Drawing No. LP0988
Verify that the proper input voltage is connected to the switch before powering on the unit.
Note:
LEDs are described in detail in
.
2.4.4
7506GX2
The 7506GX2 has a redundant 10-49 VDC power input.
1.
Unscrew and remove the AC voltage input plug from the power input header.
2.
Install the AC power cables into the plug (observing polarity).
3.
Plug the voltage input plug back into the power input header.
This is the
power disconnect device that must be removed before performing any kind of
service or maintenance on the device.
4.
Tightening torque for the terminal block power plug is 0.5 Nm/0.368 lb/ft.
5.
Verify that the power LED is on (Green).
Note:
When a AC power supply is installed (i.e., the -AC option), use 12-24 AWG (0.205mm
²
-
3.31mm
²)
wire when connecting to the power supply.