Revised 2019-08-22
Hardware Installation
Drawing No. LP0988
Connecting the Switch
2-70
N-Tron
®
Series 700/7000 Managed Industrial Ethernet Switch Hardware Manual - Volume II
The following table shows the pin-out and the connections for both types of cable:
2.6.4
HyperTerminal
Terminal
Interface
The following configuration should be used in HyperTerminal.
2.6.5
USB
Interface
These switches provide a USB interface accessed via the USB connector labeled as “USB” on the unit. This is
used to access the Command Line Interpreter (CLI). Each switch USB port location is provided below:
2.6.5.1 USB
Cable
Connect the USB port of your PC and the Switch using a standard USB cable. This requires a cable with a Type A
connector for the PC end, and a Type B connector for the Switch end.
Standard USB cables are available from a variety of suppliers.
PC Port
25-Pin Female
9-Pin Female
7900 Model 9-Pin Male
Signal Name
Pin #
Pin #
Pin #
Signal Name
TXD
2
3
3
RXD
RXD
3
2
2
TXD
GND
7
5
5
GND
Setting
Value
Port Settings:
115200
Data Bits:
8
Parity:
None
Stop Bits:
1
Flow Control:
None
Model
709FX
710FX2
711FX3
712FX4
714FX6
7010TX
7012FX2
7026TX
7506GX2
Location
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Front
Front