N-Tron
®
Series 700/7000 Managed Industrial Ethernet Switch Hardware Manual - Volume II
1-29
Product Overview
Revised 2019-08-22
7026TX
Drawing No. LP0988
1.10.2
7026TX
Specifications
Mechanical
Height
Width
Depth
Weight
Mount
1.75" (4.45 cm)
19.0" (48.26 cm)
5.4" (13.7 cm)
5.5 lbs (2.5 kg)
Rack/Panel
Power Input
Input Voltage
Steady Input Current
BTU/hr
18-49 VDC (Regulated)
605 mA @ 24 VDC
49.6 @ 24 VDC
90-264 VAC*
215 mA @ 120 VAC*
100 @ 120 VAC*
90-300 VDC*
110 mA @ 124 VDC*
47 @ 124 VDC*
Environmental
Operating
Temperature
Storage Temperature Operating Humidity
Operating Altitude
-40 °C to 80 °C
-40 °C to 85 °C
5% to 95% (non condensing)
0 to 10,000 ft.
Shock and Vibration
Shock
Vibration
Note
200g @ 10 ms
50g, 5-200Hz, Triaxial
Unit must be bulkhead mounted to achieve these
levels.
Connectors
10/100BaseTX: 24 RJ45 copper ports
Optional SFP Ports: 1000BaseT: Up to two RJ45 gigabit copper ports or,
1000BaseSX/LX: Up to two LC duplex gigabit fiber ports
Recommended Minimum Wiring Clearance
Top
1" (2.54 cm)
Front
4” (10.16 cm)
Back
1" (2.54 cm) (7026TX)
2” (5.08 cm) (7026TX-AC)
Bottom
1" (2.54 cm)
Network Media
10BaseT
100BaseTX
1000BaseT
1000BaseSX
1000BaseLX
≥CAT3 Cable
≥CAT5 Cable
≥CAT5E Cable
Multimode:
50-62.5/125µm
Singlemode:
7-10/125µm
Switch Properties
Number of MAC Addresses
Aging Time
Latency (Typical)
Switching Method
8,000
Programmable
2.6 µs
Store & Forward
Refer to
“Gigabit Fiber Transceiver (SFP) Characteristics”
* 7026TX-AC model