Using a Remote Unit
SE4000 MPEG-2 Contribution Encoder
4-16
01-0934-401-B
SE4000 Remote Command Descriptions
Remote Command
Parameter
Range
Factory
Default
Description
MC RE
-
-
Resets the SE4000, reloads all programmable logic
and firmware, and restarts the system. All
parameters return to the last settings stored in flash
memory or the last changes made using the front
panel. The SE4000 restores configuration settings
as follows:
? All changes made using the front panel are
automatically stored in flash memory. When
the SE4000 is reset, any changes made
using the front panel are restored.
? Changes made using a remote unit are not
automatically stored in flash memory. If the
SE4000 is reset before issuing the CM SAVE
command, changes made using a remote unit
are not restored. Instead, the last changes
saved to flash memory are restored.
? If the SE4000 configuration is changed using
a remote unit, an operational test should be
performed to verify system operations. Then
the new configuration should be saved by
issuing the CM SAVE command. Once the
configuration is saved, the SE4000
automatically restores the saved settings
when the unit is reset or powered up.
Note: The SE4000 real- time clock includes a
battery backup source. If the unit loses power,
is turned off, or reset, the real-time clock
reverts to the current day and time. This
backup power will only last for approximately
one week.
Front panel command equivalent:
Config>Control>Reset
MC STOP
1, 2
1
Sets the number of stop bits for the RS-232 remote
control port.
Front panel command equivalent:
Config>Comm>Serial>Stop Bits
MC TIME
hh:mm:ss
Numeric value
in the format:
hh:mm:ss
-
Sets the SE4000 internal real-time clock. The time
is set in hh:mm:ss format where:
? hh = hours, in a 24-hour format, from 00 to
23, where 00 is midnight and 23 is 11 PM
? mm = minutes from 00 to 59
? ss = seconds from 00 to 59
For example, to set the time to 10:20:59 AM, issue
the command MC TIME 10:20:59. To set the time
to 10:20:59 PM, issue the command MC TIME
22:20:59.
Note: The SE4000 real- time clock does have a
battery backup source. If the unit loses power,
is turned off, or reset, the real-time clock is set
to the current (correct) day and time.
Front panel command equivalent:
Config>Control>Clock>Time
MC VERSION
-
-
Displays the firmware version of the master
controller card.
Front panel command equivalent: none
MC FPPASSWD
<string>
7348
Unlocks the Front panel
Summary of Contents for TIERNAN SE4000
Page 2: ......
Page 12: ...Preface SE4000 MPEG 2 Contribution Encoder xii 01 0934 401 B...
Page 103: ...Configuring the SE4000 SE4000 MPEG 2 Contribution Encoder 5 6 01 0934 401 B...
Page 115: ...Troubleshooting SE4000 MPEG 2 Contribution Encoder 6 12 01 0934 401 B...
Page 117: ...Maintenance and Software Upgrades SE4000 MPEG 2 Contribution Encoder 7 2 01 0934 401 B...
Page 121: ...Technical Specifications SE4000 MPEG 2 Contribution Encoder A 4 01 0934 401 B...
Page 141: ...Conditional Access SE4000 MPEG 2 Contribution Encoder C 12 01 0934 401 B...
Page 161: ...Glossary SE4000 MPEG 2 Contribution Encoder GL 12 01 0934 401 B...