SE4000 MPEG-2 Contribution Encoder
Troubleshooting
01-0934-401-B
6-9
SE4000 Fault Summary
Front Panel
Display
Remote Unit
Display
Description
Action Required
Digital Video Input
AE.x Init
AE.x Init Error
Audio Init Error
Power cycle the unit.
If normal
operations do
not resume,
contact the
Radyne
ComStream
Customer
Service
Department..
AE. X Inp
Invd
AE.x AESEBU
Input Loss
AESEBU Input Error
If unit is functioning normally, clear faults
and continue operations.
If faults continue check connection;
ensure input source is in proper format
and conforms to specified input levels.
If unit continues to fail, contact the
Radyne ComStream Customer Service
Department.
AE.x L-Ch
Idle
AE.x Left
Channel Idle
Left Channel Idle
Status message – informational only.
Continue operations.
AE.x
PesUndFlw
AE.x PES FIFO
Overflow
Audio PES (packetized
elementary stream)FIFO
Full
MuX rate is set too low.
Recalculate all bit rates and enter correct
rates, or select Auto Mode.
AE.x
PesUndFlw
AE.x PES FIFO
Underflow
Audio PES (packetized
elementary stream)FIFO
Empty
If unit is functioning normally, clear faults
and continue operations.
Contact the Radyne ComStream
Customer Service Department.
AE.x R-ch
Idle
AE.x Right
Channel Idle
Right Channel Idle
Status message – informational only.
Continue operations.
MOD.x Init
MOD. X Init
Error
Modulator Initialization
Error
Power cycle the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
MOD.x Inp
Loss
MOD.x Loss of
Input
Modulator is not receiving
the transport stream.
Verify the connections.
Set modulator input to backplane.
Ensure Mux Rate = the Modulator rate.
MOD.x LO
Lock
MOD.x Local
Oscill Unlocked
Modulator Loss of Local
Oscillator Lock
Verify the connections.
Set modulator input to backplane.
Ensure Mux Rate = the Modulator rate.
MOD.x No
Mux
MOD.x No
Local Input
Source
Modulator is not receiving
the transport stream.
Verify the connections.
Set modulator input to backplane.
Ensure Mux Rate = the Modulator rate.
MOD.x SC
Lock
MOD.x Symbol
Clock Unlocked
Modulator Loss of Symbol
Clock Lock
Verify the connections.
Set modulator input to backplane.
Ensure Mux Rate = the Modulator rate.
no front
panel fault
S/W Error:
Software trap
encountered.
Internal software error.
Reset the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
no front
panel fault
S/W Error:
Software
exception
encountered.
Internal software error.
Reset the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
Summary of Contents for TIERNAN SE4000
Page 2: ......
Page 12: ...Preface SE4000 MPEG 2 Contribution Encoder xii 01 0934 401 B...
Page 103: ...Configuring the SE4000 SE4000 MPEG 2 Contribution Encoder 5 6 01 0934 401 B...
Page 115: ...Troubleshooting SE4000 MPEG 2 Contribution Encoder 6 12 01 0934 401 B...
Page 117: ...Maintenance and Software Upgrades SE4000 MPEG 2 Contribution Encoder 7 2 01 0934 401 B...
Page 121: ...Technical Specifications SE4000 MPEG 2 Contribution Encoder A 4 01 0934 401 B...
Page 141: ...Conditional Access SE4000 MPEG 2 Contribution Encoder C 12 01 0934 401 B...