Troubleshooting
SE4000 MPEG-2 Contribution Encoder
6-10
01-0934-401-B
no front
panel fault
S/W Error:
VxWorks
internal signal
caught.
Internal software error.
Reset the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
no front
panel fault
S/W Error:
Hardware
exception
caught
Internal software error>
Reset the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
TAB.x Init
TAB. X Init
Error
Table Initialization Error
Power cycle the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
VE.x Init
VE.x Init Error
Video Encounter
Initialization Error
Power cycle the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
VE.x
EncOvrflw
VE.x ENC FIFO
Overflow
Video FIFO (first in, first
out) Overflow
MUX rate is set too low.
Recalculate all bit rates and enter correct
rates, or select AUTO mode.
VE.x
PesOvrflw
VE.x PES FIFO
Overflow
Video PES (packetized
elementary stream)
Overflow
MUX rate is set too low.
Recalculate all bit rates and enter correct
rates, or select AUTO mode.
VI.x
FormatErr
VI.x Format
Mismatch
Analog Video Format
Mismatch. Input format
does not match set
configuration
Verify that the source format matches
configuration.
If unit continues to fail, contact the
Radyne ComStream Customer Service
Department.
VI.x Gen
Loss
VI.x Loss of
Genlock
Analog Genlock Input is not
present.
If Genlock source was enabled, ensure
input source is in proper video format and
conforms to specified input levels.
If the unit continues to fail, disable
GenLock.
VI. x Init
VI.x Init Error
Video Initialization Error
Power cycle the unit.
If normal operations do not resume,
contact the Radyne ComStream
Customer Service Department.
VI. x Inp
Level
VI.x Input Level
Large
Analog Video Input Too
Large
Ensure that the input source is in proper
video format and conforms to specified
input levels.
Adjust video input signal levels.
Ensure video is terminated.
VI.x Inp
Level
VI.x Input Level
Small
Analog Video Input Too
Small
Ensure that the input source is in proper
video format and conforms to specified
input levels.
Adjust the video input signal levels.
VI.x Inp Loss VI.x Loss of
Input
Video Main Input Not
Present
If the unit is functioning normally, clear
faults and continue operations. If faults
continue, check connections, ensure input
source is in proper video format and
conforms to specified input levels.
If unit continues to fail, reset unit.
VI.x Ovrflw
VI.xD1 FIFO
Overflow
Ditgital Video D1 Video
FIFO (first in, first out ) is
full
If the unit is functioning normally, clear
faults and continue operations. If faults
continue, check connections, ens ure input
source is in proper video format and
conforms to specified input levels.
If unit continues to fail, reset unit.
VI.x Ovrflw
VI.x FIFO
Overflow
Analog D1 Video FIFO (first
in, first out ) overflow
If the unit is functioning normally, clear
faults and continue operations. If faults
continue, check connections, ensure input
source is in proper video format and
Summary of Contents for TIERNAN SE4000
Page 2: ......
Page 12: ...Preface SE4000 MPEG 2 Contribution Encoder xii 01 0934 401 B...
Page 103: ...Configuring the SE4000 SE4000 MPEG 2 Contribution Encoder 5 6 01 0934 401 B...
Page 115: ...Troubleshooting SE4000 MPEG 2 Contribution Encoder 6 12 01 0934 401 B...
Page 117: ...Maintenance and Software Upgrades SE4000 MPEG 2 Contribution Encoder 7 2 01 0934 401 B...
Page 121: ...Technical Specifications SE4000 MPEG 2 Contribution Encoder A 4 01 0934 401 B...
Page 141: ...Conditional Access SE4000 MPEG 2 Contribution Encoder C 12 01 0934 401 B...
Page 161: ...Glossary SE4000 MPEG 2 Contribution Encoder GL 12 01 0934 401 B...