SE4000 MPEG-2 Contribution Encoder
Using a Remote Unit
01-0934-401-B
4-13
SE4000 Remote Command Descriptions
Remote Command
Parameter
Range
Factory
Default
Description
CM RENAME <
old
label
>;<
new label
>
Where <
old
label
>
specifies the
current user-
defined label
and <
new
label
> defines
the new label
name.
-
Renames an existing label
Fwont panel command equivalent:
Config>Presets>Rename
CM RESTORE
<string>
1
Where
string
specifies a
user-defined
label or factory
defined label of
DVB, ATSC.
DVB
Recalls one of the factory- or user-defined
configuration sets from memory and saves it in
flash memory as the current configuration (i.e.,
power-up or reset restores the configuration set).
For example, to restore or load the configuration
set labeled SD MCPC, issue the command CM
LOAD CD MCPC
Note: When the SE4000 is set to the DVB
default setting, the remote port baud rate is set
to 38400 bps. If the remote unit is set to
communicate with the SE4000 at a baud rate
other than 38400 bps, immediately after the
DVB default command is issued, the remote
unit will not be able to communicate with the
SE4000. To resolve this issue, the equivalent
parameter in the software settings of the
remote unit must be changed to 38400 bps.
However, the remote unit software settings
must not be changed before issuing the DVB
default command to the SE4000, as the remote
unit will not be able to communicate with the
SE4000.
Front panel command equivalent:
Config>Presets>Restore
CM SAVE
1
-
-
Saves the current configuration to flash memory.
Front panel command equivalent: none
CM SAVE_CFG
<
string
>
1
Where
string
specifies a
user-defined
label.
-
Saves the current configuration settings to the
specified user-defined label. The user label must
be created using the CM CREATE command prior
to storing the configuration settings.
For example, to store the unit’s current
configuration settings to the existing user
configuration label SD MCPC, issue the command:
CM SAVE_CFG SD MCPC.
Caution: Any configuration parameters
previously saved under a specified label are
overwritten and lost when a new configuration
set is saved to the same location.
Front panel command equivalent:
Config>Presets>Save
FM CURR_LIST
-
-
Query only command, displays all current faults.
Front panel command equivalent: Status>Current
FM LOG_CLR
-
-
Clears the fault history log.
Note: Clearing the fault history log does
not clear the fault relay.
Front panel command equivalent:
Status>History>Clear
Summary of Contents for TIERNAN SE4000
Page 2: ......
Page 12: ...Preface SE4000 MPEG 2 Contribution Encoder xii 01 0934 401 B...
Page 103: ...Configuring the SE4000 SE4000 MPEG 2 Contribution Encoder 5 6 01 0934 401 B...
Page 115: ...Troubleshooting SE4000 MPEG 2 Contribution Encoder 6 12 01 0934 401 B...
Page 117: ...Maintenance and Software Upgrades SE4000 MPEG 2 Contribution Encoder 7 2 01 0934 401 B...
Page 121: ...Technical Specifications SE4000 MPEG 2 Contribution Encoder A 4 01 0934 401 B...
Page 141: ...Conditional Access SE4000 MPEG 2 Contribution Encoder C 12 01 0934 401 B...
Page 161: ...Glossary SE4000 MPEG 2 Contribution Encoder GL 12 01 0934 401 B...