![RADVision SCOPIA 400 User Manual Download Page 141](http://html1.mh-extra.com/html/radvision/scopia-400/scopia-400_user-manual_3359507141.webp)
Configuring the SCOPIA Gateway
131
Configuring Port Settings
7
In the Signaling type field, choose the signaling type.
8
Click
OK
to close the Advanced dialog box.
S
ERIAL
P
ORTS
This section applies only to Gateway S40 SP.
In the
Physical Interface
section of the Serial
Port
tabs, you can control the
properties of the cable connected to the specified serial port. When a cable is
connected to a serial port, the Gateway identifies the type of the cable and
displays the information in the
Interface
and
Physical standard
fields of the
Physical Interface
section. In such cases, you cannot modify these fields. If the
Gateway does not detect a connected cable, you can modify the
Interface
and
Physical standard
fields. For changes to settings in these fields to take effect,
the system should be rebooted.
Gateway line cables are attached to the Gateway via a DB-60 connector that
provides the serial line connection for the Gateway serial ports. The cables are
Y-type with split leads at the remote end. On one side is either a V.35, RS-449,
EIA-530, or EIA-530A connector. On the other side is an RS-366 connector.
Gateway terminal adapter cables have either a DTE or a DCE interface.
The Gateway can identify which type of cable has been connected to its DB-60
serial ports. Cable configuration settings are automatically displayed in the
Physical Interface
section of the
Port
tabs. The automatically configured
settings are shown in
Table 3-19
on page 132.
Procedure
1
In the Gateway interface, on the sidebar, click
Gateway
(if not already
selected).
2
Click the applicable Port tab.
3
Click the
Physical Interface
button.
4
In the
Interface
field, select the DTE or DCE cable interface (disabled
after you have connected a cable).
The
Physical standard
field displays the type of line connected to the
serial port.
5
In the
Terminal adapter
field, select the required terminal adapter type.
Enabled only when
DTE
is selected in the
Interface
field. When
DCE
is selected in the
Interface
field, the
Terminal adapter
option is set to
Common
and disabled.
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 1000 Gateway version 5 6 User Guide...
Page 10: ......
Page 70: ...60 SCOPIA 400 1000 Gateway User Guide Registering the Online Help...
Page 166: ...156 SCOPIA 400 1000 Gateway User Guide Importing Configuration Files...
Page 198: ...188 SCOPIA 400 1000 Gateway User Guide Using Express Setup...
Page 202: ...192 SCOPIA 400 1000 Gateway User Guide Upgrading Software...