106
SCOPIA 400/1000 Gateway User Guide
Configuring Gateway Settings
Call to peer
rejected - trying
alternate
A call to a peer has been rejected and the
Gateway is searching for an alternate peer.
Warning
Call to peer
rejected by all
listed peers
A call to a peer has been rejected by all
listed peers.
Major
Card extract/Hot
Swap
A blade has been removed from the
RADVISION
chassis under power or
inserted into the chassis under power, or the
when the Gateway enters maintenance
mode.
TRUE Critical
FALSE
Clear
Configuration
changed
A configuration change is uploaded from the
web interface.
Information
Configuration
exported
Configuration is exported via the web
interface.
Information
Configuration
imported
Configuration is imported via the web
interface.
Information
Corrupt IVR
messages on host
Corrupt IVR files are present in the
Gateway.
Warning
Corrupt WEB
data
Corrupt web files are present in the
Gateway.
Major
Gatekeeper
registration state
change
A change occurs in the registration status of
the Gateway.
TRUE Clear
FALSE
Minor
Incompatible sw
version install
An attempt to burn a version of the Gateway
software onto incompatible hardware
occurs.
Warning
Loss of Ethernet
The network returns after going down.
Indicates the time at which the network was
restored.
TRUE Critical
FALSE
Clear
Table 3-10
Serial Gateway SNMP Trap Event Types (continued)
Event Type
Trap is sent when ...
State
Severity
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 1000 Gateway version 5 6 User Guide...
Page 10: ......
Page 70: ...60 SCOPIA 400 1000 Gateway User Guide Registering the Online Help...
Page 166: ...156 SCOPIA 400 1000 Gateway User Guide Importing Configuration Files...
Page 198: ...188 SCOPIA 400 1000 Gateway User Guide Using Express Setup...
Page 202: ...192 SCOPIA 400 1000 Gateway User Guide Upgrading Software...