112
SCOPIA 400/1000 Gateway User Guide
Configuring Gateway Settings
Table 3-12
Advanced Settings—IP to ISDN (or Serial) Calls
Field or Check Box
Description
Conceal caller ID
(unavailable in
Gateway S40 SP)
Select to cause the Gateway to hide the identifier of the
calling endpoint on the IP network, regardless of whether or
not the
Support Presentation Restriction advanced setting is
selected. The
callerID
field of the Q.931 message is sent
over the ISDN network empty.
Ignore caller bearer rate
and force service rate
Select to configure the Gateway to ignore the incoming call
bearer rate and to use instead the bandwidth specified for the
service on the Services tab to process the call. If the service
bit rate is set to
Auto
, the Gateway process the call at the
bearer rate.
Deselect to allow an administrator to limit a specific service
to a maximum bit rate. When deselected and the bearer rate
is greater than the service rate, the Gateway processes the
call at the service rate. When deselected and the bearer rate
is lower than or equal to the service rate, the Gateway
processes the call at the bearer rate. If the bearer bit rate is
set to Auto, the Gateway process the call at the bearer rate.
Summary of Contents for SCOPIA 400
Page 1: ...SCOPIA 400 1000 Gateway version 5 6 User Guide...
Page 10: ......
Page 70: ...60 SCOPIA 400 1000 Gateway User Guide Registering the Online Help...
Page 166: ...156 SCOPIA 400 1000 Gateway User Guide Importing Configuration Files...
Page 198: ...188 SCOPIA 400 1000 Gateway User Guide Using Express Setup...
Page 202: ...192 SCOPIA 400 1000 Gateway User Guide Upgrading Software...