Chapter 6 - Maintenance
Replacing the Backup Battery
75
5
Remove the four #4 Phillips Flat head screws that secure the Battery Access Plate.
Refer to the illustration on the following page.
6
Lift the Battery Access Plate from the controller cage assembly about 1 inch. Reach in
and disconnect the power cable connecting the BBU to the controller circuit board.
7
Remove the battery from the Battery Access Plate by removing the two #4 Phillips
screws. Note the orientation.
8
Remove your new replacement battery from is shipping package and inspect for
obvious damage.
9
Attach the new battery to the Battery Access Plate. Using the two #4 Phillips screws
previously removed, secure the battery. Refer to the illustration on the previous page.
10
Connect the BBU power cable to the controller circuit board at J8. The connector is
keyed and will only install one way.
11
Secure the Battery Access Plate to the controller cage using the four #4 Phillips Flat
head screws previously removed.
12
Reinsert the RAID Controller into the enclosure and secure it with the latches.
13
Power on the storage system. During the power up self test the battery status will be
updated. Refer to “Powering On the Storage System” on page 41.
14
Using the packaging materials from the replacement backup battery unit, repackage
and return it per your RMA instructions, if applicable.
Summary of Contents for OmniStor 4700S Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 8: ...Table of Contents iv...
Page 54: ...Chapter 3 Setup and Installation Powering Off the Storage System 42...
Page 90: ...Chapter 6 Maintenance Replacing the Enclosure 78...
Page 94: ...Appendix A Technical Information Specifications 82...
Page 108: ...Index 96...