Chapter 4 - Managing and Monitoring
VT-100 Interface Enclosure Monitoring
49
If your host terminal (or program) communication settings do not match the
controller, it will not communicate. The controller has the ability to automatically set
itself to match the terminal settings.
a
After the enclosure has completed its power on self test (2 quick beeps along with
the far left three drive Status LEDs blinking amber and green), press and hold the
<Enter> key.
This process takes you to what is called the “Monitor mode.” Once in Monitor
mode (command prompt displayed), type “rs” and press <Enter>. This will restart
the controller using the corrected communication settings.
7
If the menu system does not automatically appear after the controller has completed
its boot cycle, at the screen cursor type <Control-E>. Then type <Control-W> to
switch the interface to the menu-based mode.
Main Menu Screen
8
To monitor the enclosure components, use the <Up> and <Down> Arrow keys to
select Enclosure Information and press <Enter>.
The screen displays the status of the internal components such as disk drives present,
temperature of the thermal sensors, cooling fan status, power supply status, and alarm
status.