background image

A – Command Line Interface

User Command

59226-00 B

A-95

A

User Command

Administers and displays user accounts.

Authority

Admin account name and an Admin session. The Accounts and List keywords are 
available to all account names without an Admin session.

Syntax

user

accounts
add
delete [account_name]
edit
list

Keywords

accounts

Displays all user accounts that exist on the switch. This keyword is available to all 
account names without an Admin session.

add

Add a user account to the switch. You will be prompted for an account name, a 
password, authority, and an expiration date.

„

A switch can have a maximum of 15 user accounts.

„

Account names are limited to 15 characters; passwords must be 4–20 
characters.

„

Admin authority grants permission to use the Admin command to open an 
admin session, from which all commands can be entered. Without Admin 
authority, you are limited to view-only commands.

„

The expiration date is expressed in the number of days until the account 
expires (2000 maximum). The switch will issue an expiration alarm every 
day for seven days prior to expiration. 0 (zero) specifies that the account has 
no expiration date.

delete [account_name]

Deletes the account name given by [account_name] from the switch.

edit

Initiates an edit session that prompts you for the account name for which to 
change the expiration date and authority.

list

Displays the list of users currently logged in and their session numbers. Provides 
the same function as the Show Users command. This keyword is available to all 
account names without an Admin session.

Summary of Contents for SANbox 1400 Series

Page 1: ...S i m p l i f y R 59226 00 B Page i SANbox 1400 Series Switch Management User s Guide Firmware Version 5 0...

Page 2: ...o responsibility for any errors that may appear in this document QLogic SANbox SANsurfer SANblade SANsurfer Switch Manager and SANsurfer Management Suite are trademarks or registered trademarks of QLo...

Page 3: ...laris 2 8 2 3 Starting SANsurfer Switch Manager 2 10 2 4 Exiting SANsurfer Switch Manager 2 13 2 5 Uninstalling SANsurfer Switch Manager 2 15 2 5 1 SMS Uninstall 2 15 2 5 2 Standalone Uninstall 2 16 2...

Page 4: ...e Data Windows 2 32 Section 3 Managing Fabrics 3 1 Fabric Security 3 1 3 1 1 User Account Security 3 1 3 1 2 Fabric Services 3 2 3 1 2 1 Enabling SNMP Configuration 3 2 3 1 2 2 Enabling In band Manage...

Page 5: ...Exporting Nicknames to a File 3 19 3 5 3 5 Importing a Nicknames File 3 20 3 6 Zoning a Fabric 3 20 3 6 1 Zoning Concepts 3 20 3 6 1 1 Zones 3 21 3 6 1 2 Aliases 3 22 3 6 1 3 Zone Sets 3 22 3 6 1 4 Z...

Page 6: ...brics and Zoning 3 39 3 6 7 1 Zone Merge Failure 3 39 3 6 7 2 Zone Merge Failure Recovery 3 40 Section 4 Managing Switches 4 1 Managing User Accounts 4 2 4 1 1 Creating User Accounts 4 3 4 1 2 Removin...

Page 7: ...4 7 5 1 SNMP Configuration 4 29 4 7 5 2 SNMP Trap Configuration 4 30 4 8 Archiving a Switch 4 31 4 9 Restoring a Switch 4 32 4 10 Restoring the Factory Default Configuration 4 34 4 11 Downloading a Su...

Page 8: ...or a Switch 5 23 5 6 7 1 Arranging Graphs in the Display 5 24 5 6 7 2 Customizing Graphs 5 24 5 6 7 3 Setting Global Graph Type 5 26 5 6 7 4 Rescaling a Selected Graph 5 26 5 6 8 Printing Graphs 5 27...

Page 9: ...ig Command A 40 Set Log Command A 51 Set Port Command A 55 Set Setup Command A 57 Show Command A 62 Show Config Command A 77 Show Log Command A 81 Show Perf Command A 85 Show Setup Command A 87 Shutdo...

Page 10: ...User Account Administration Dialog Add Account 4 3 4 2 User Account Administration Dialog Remove Account 4 4 4 3 User Account Administration Dialog Change Password 4 5 4 4 User Account Administration...

Page 11: ...s 5 3 5 3 Port Speeds 5 3 5 4 Port Transceiver Media View 5 4 5 5 Port Statistics Data Window Entries 5 5 5 6 Port Information Data Window Entries 5 7 5 7 Port Administrative States 5 11 5 8 Port Spee...

Page 12: ...Page xii 59226 00 B SANbox 1400 Series Switch Management User s Guide S Notes...

Page 13: ...audience for this manual related materials and technical support Section 2 describes how to use SANsurfer Switch Manager its menus and its displays Section 3 describes fabric management tasks Section...

Page 14: ...nclude in the end user documentation provided with the redistribution and or in the software itself an acknowledgement equivalent to the following This product includes software developed by the JDOM...

Page 15: ...nty is available during local standard working hours excluding QLogic Observed Holidays 1 4 2 Training QLogic offers certification training for the technical professional for both the SANblade HBAs an...

Page 16: ...one 1 952 932 4040 Fax 1 952 932 4018 Europe Middle East and Africa Region Email emeasupport qlogic com Phone Numbers by Language 353 1 6924960 English 353 1 6924961 Fran ais 353 1 6924962 Deutsch 353...

Page 17: ...nt Application Starting SANsurfer Switch Manager Exiting SANsurfer Switch Manager Uninstalling SANsurfer Switch Manager Changing the Encryption Key for the Default Fabric View File Saving and Opening...

Page 18: ...es If your switch was shipped with a SANsurfer Switch Manager Disk refer to SANsurfer Switch Manager on page 2 3 for instructions on how to install SANsurfer Switch Manager If your switch was shipped...

Page 19: ...all 3 Double click on the Windows_5 00 xx exe file to begin installation If the product introduction screen does not open in step 2 open the CD with Windows Explorer and run the installation program w...

Page 20: ...tallation instructions 2 2 2 SANsurfer Management Suite The following instructions describe how to install SANsurfer Management Suite and upgrade SANsurfer Switch Manager You can install SANsurfer Man...

Page 21: ...the left pane From the Help menu select About and make note of the version number Close SANsurfer Management Suite 8 To ensure you are using the most recent version of SANsurfer Switch Manager visit...

Page 22: ...n do the following a Open an xterm or other terminal window b Mount the CD ROM From a shell prompt enter the following command mount mnt cdrom c Execute your web browser to view the Start_Here htm doc...

Page 23: ...e version number 5 00 xx is greater than what is currently installed on your workstation down load the new version and proceed to step 11 Otherwise no upgrade is needed and the SMS installation is com...

Page 24: ...e SANsurfer Management Suite start page click the SANbox Switch Software button 3 On the SANbox Switch Software page scroll to the SANbox 1400 area 4 In the Operating System column click the Solaris S...

Page 25: ...e SANsurferSwitchMgr_QLGCsol_5 00 xx bin file in a folder and make the file executable chmod x sansurferswitchmgr_QLGCsol_x xx xx 12 Install the new SANsurfer Switch Manager package pkgadd d sansurfer...

Page 26: ...urfer Switch Manager application From a command line you can enter the SANsurfer_Switch_Manager command install_directory SANsurfer_Switch_Manager exe For Linux Solaris or Mac OS X enter the SANsurfer...

Page 27: ...urfer command install_directory SANsurfer 2 From the SANsurfer Management Suite home page click the SANsurfer Switch Manager button 3 In the Initial Start dialog click the Open Configuration Wizard bu...

Page 28: ...on to open the Open View dialog which prompts you to specify a fabric view file that you saved earlier Refer to Opening a Fabric View File on page 3 6 Click the Start Application Without Specifying a...

Page 29: ...he working directory Figure 2 3 Save Default Fabric View File Dialog The encryption key is used to encrypt the sensitive data in the default fabric view file Refer to Changing the Encryption Key for t...

Page 30: ...to load the default fabric view file and to specify its encryption key if there is one In the Default Fabric File Encryption Key field enter the encryption key and click the Load View File button If y...

Page 31: ...e The UninstallData folder in the installation directory contains the uninstall program SANsurferUninstaller The default installation directories are For Windows C Program Files QLogic_Corporation SAN...

Page 32: ..._Switch_Manager For Solaris usr opt QLogic_Corporation SANsurfer_Switch_Manager For MacOS X Users qlogic Applications QLogic_Corporation SANsurfer_Switch_Manager To uninstall the SANsurfer Switch Mana...

Page 33: ...the SANsurfer Switch Manager default fabric view file you can save and open your own fabric view files To save a set of fabrics to a file do the following 1 Open the File menu and select Save View As...

Page 34: ...e Nonsecure Connection Check dialog upon login when establishing a nonsecure connection Enable default or disable the Event Browser Refer to Displaying the Event Browser on page 3 11 If the Event Brow...

Page 35: ...save the changes Figure 2 5 Preferences Dialog SANsurfer Switch Manager 2 9 Using Online Help Online help is available for the SANsurfer Switch Manager application and its functions The two ways to o...

Page 36: ...isplay and the faceplate display The topology display shows all switches that are able to communicate and all connections between switches The faceplate display shows the front of a single switch and...

Page 37: ...nus and the options offered in them vary depending on the display For example the Port menu and many of the Switch menu selections are available only in the faceplate display 2 11 1 1 Topology Display...

Page 38: ...the menu bar both the topology and faceplate displays have context sensitive menus that pop up when you right click in the graphic window Refer to Opening the Faceplate and Topology Display Popup Men...

Page 39: ...the handle at the left edge of the tool bar Table 2 2 Tool Bar Buttons Tool Bar Button Description Add Fabric button adds a new fabric to the fabric view Open View File button opens an existing fabric...

Page 40: ...tus A green icon indicates normal operation A yellow icon indicates that a switch is operational but may require attention to maintain maximum performance A red icon indicates a potential failure or n...

Page 41: ...adjusted by clicking and dragging the border that it shares with the graphic window Adjust the column width by moving the pointer over the column heading border shared by two columns until a right lef...

Page 42: ...Figure 2 10 receives information from the selected fabric and displays its topology Switches and inter switch links ISLs appear in the graphic window and use color to indicate status Consider the fol...

Page 43: ...s You select switches and links to display information about them modify their configuration or delete them from the display Context sensitive popup menus are displayed when you right click on a switc...

Page 44: ...d restore that layout during a SANsurfer Switch Manager session Begin by arranging the icons then open the View menu and select Remember Layout To restore the saved layout open the View menu uncheck t...

Page 45: ...formation Active Zoneset displays the active zone set for the fabric including zones and their member ports Refer to Active Zone Set Data Window on page 3 16 for more information about this data windo...

Page 46: ...1 Faceplate Display 2 13 1 Port Views and Status Port color and text provide information about the port and its operational state Green indicates active gray indicates inactive The faceplate display p...

Page 47: ...s in between in port number sequence To select several non consecutive ports hold the Control key while selecting To select all ports right click on the faceplate image Select Select All Ports from th...

Page 48: ...the data window tabs Devices displays information about devices hosts and storage targets connected to the switch Switch displays current switch configuration data Port Statistics displays performanc...

Page 49: ...ou attempt to add a fabric using SANsurfer Switch Manager or log in to a switch through Telnet Your system administrator defines accounts passwords and authority levels that are stored on the switch R...

Page 50: ...he ability to manage switches across inter switch links using SANsurfer Switch Manager SNMP management server or the application programming interface The switch comes from the factory with in band ma...

Page 51: ...device hardware drivers and firmware version from FDMI The Snapshot Analyzer option enables you to Compare two snapshots Detect mismatches of firmware and driver versions Detect devices that have bee...

Page 52: ...each pane At the top of the separator bar between the two panes click the left right arrows to close the corresponding pane The left right arrows move to one side 3 2 3 Exporting Version Snapshots to...

Page 53: ...name and password are admin and password The password is for the switch and is stored in the switch firmware Refer to Managing User Accounts on page 4 2 for information about creating user accounts 4...

Page 54: ...In the Open View dialog enter the name of the file to open and enter a file password if a password was entered when this fabric view file was saved 3 Click the OK button 3 3 4 Saving a Fabric View Fil...

Page 55: ...Fabric zoning is sent to the switch from the fabric All ports will be GL_Ports The default IP address 10 0 0 1 is assigned to the switch without a gateway or boot protocol configured RARP BOOTP and D...

Page 56: ...ve and restore Use the following procedure to replace a failed switch for which an archive is available 1 At the failed switch a Turn off the power and disconnect the AC cords b Note port locations an...

Page 57: ...Ethernet connection to the management workstation The data window tabs show device switch and active zone set information The Active Zoneset tab shows the zone definitions for the active zone set Refe...

Page 58: ...ition that may require attention to maintain maximum performance and red indicates a potential failure Table 3 1 shows the different switch icons and their meanings Table 3 1 Topology Display Switch a...

Page 59: ...use the switch time stamp while event entries generated by the application have a workstation time stamp You can filter sort and export the contents of the Event Browser to a file The Event Browser be...

Page 60: ...e attention from a user or service representative Warning event An event that indicates errors or other conditions that may require attention to maintain maximum performance Warning mes sages will not...

Page 61: ...a will be shown You can filter the event browser in the following ways Severity Check one or more of the corresponding check boxes to display alarm events critical events warning events or informative...

Page 62: ...scription Successive sort operations of the same type alternate between ascending and descending order 3 4 2 3 Saving the Event Browser to a File You can save the displayed Event Browser entries to a...

Page 63: ...page 3 18 for exporting device information Table 3 3 Devices Data Window Entries Entry Description Port WWN Port world wide name Nickname Device port nickname To create a new nickname or edit an exis...

Page 64: ...ow on page 4 12 for information about the zone set definitions on a particular switch Refer to Zoning a Fabric on page 3 20 for more information about zone sets and zones The Active Zoneset data windo...

Page 65: ...click the Link tab below the data window in the topology display 3 5 Working with Device Information and Nicknames SANsurfer Switch Manager enables you to do the following Displaying Detailed Device...

Page 66: ...r working directory In addition to creating editing and deleting nicknames you can also export the nicknames to a file which can then be imported into the Nicknames xml file on other workstations 3 5...

Page 67: ...K button to save the changes In the topology or faceplate display click the Devices tab to display the Devices data window Double click a cell in the Nickname column to open the Edit Nickname dialog E...

Page 68: ...ckname file in the Open dialog and click Open When prompted to overwrite existing nicknames click Yes 3 6 Zoning a Fabric Zoning enables you to divide the ports and devices of the fabric into zones fo...

Page 69: ...mber entry as you would with a WWN member Domain ID Port number entries define zone membership by switch domain ID and port number All devices attached to the specified port become members of the zone...

Page 70: ...t types 3 6 1 2 Aliases To make it easier to add a group of ports or devices to one or more zones you can create an alias An alias is a named set of ports or devices that are grouped together for conv...

Page 71: ...o active zone set Refer to Configuring the Zoning Database on page 3 28 for information about zoning configuration The following zoning limits are enforced during the configuration of zoning and durin...

Page 72: ...here must be at least one target and at least one initiator in the name server Windows servers do not share devices well but sometimes they must share devices such as a tape drive The wizard helps you...

Page 73: ...e it When you activate a zone set the switch distributes that zone set and its zones excluding aliases to every switch in the fabric This zone set is known as the active zone set You cannot edit an ac...

Page 74: ...e Error Check dialog Click the Error Check button to have SANsurfer Switch Manager check for zoning conflicts such as empty zones aliases or zone sets and ACL zones with non domain ID port number memb...

Page 75: ...create another name for a set of objects Add Member button adds selected port device to a zone Remove Member button delete the selected zone from a zone set or delete the selected port device from a...

Page 76: ...be saved to the zoning database on that switch Changes are saved when an updated zone set is activated Zoning changes are always saved to temporary memory However if Interop Auto Save is enabled the...

Page 77: ...remote switch 3 6 3 3 Saving the Zoning Database to a File You can save the zoning database to an XML file You can later reload this zoning database on the same switch or another switch To save a zoni...

Page 78: ...nd save changes to the zoning database 3 6 3 6 Removing All Zoning Definitions To clear all zone and zone set definitions from the zoning database choose one of the following Open the Edit menu and se...

Page 79: ...e Set to open the Create Zone Set dialog 3 Enter a name for the zone set and click the OK button The new zone set name is displayed in the Zone Sets dialog A zone set name must begin with a letter and...

Page 80: ...e button To deactivate the active zone set open the Zoning menu select Deactivate Zone Set Acknowledge the warning about traffic disruption and click the Yes button to confirm that you want to deactiv...

Page 81: ...e Zone Sets tree select the zone set to be removed 3 Open the Edit menu and select Remove to remove the zone set 4 Click the Apply button to save changes to the zoning database Alternatively you may u...

Page 82: ...t begin with a letter and be no longer than 64 characters Valid characters are 0 9 A Z a z _ and 5 To add switch ports or attached devices to the zone do one of the following In the zone set tree sele...

Page 83: ...Select a port device in the Port Device tree To select multiple ports devices press the Control key while selecting Select a zone set in the left pane Click the Insert button If the port device you wa...

Page 84: ...utton to save changes and close the Edit Zoning dialog 3 6 5 5 Removing a Zone from a Zone Set The orphan zone set is created by the application automatically to hold the zones which are not in any se...

Page 85: ...be zoned together An alias is not a zone and cannot have a zone or another alias as a member 3 6 6 1 Creating an Alias To create an alias do the following 1 Open the Zoning menu and select Edit Zoning...

Page 86: ...ice tree To select multiple ports devices press the Control key while selecting Select an alias Click the Insert button If the port device you want to add is not in the Port Device tree you can add it...

Page 87: ...If a zone merge is unsuccessful the inter switch links between the fabrics will isolate due to a zone merge failure which will generate an alarm The reason for the E_Port isolation can also be determi...

Page 88: ...After correcting the zone membership reset the isolated ports to allow the fabrics to join Refer to Managing Zones on page 3 33 for information about adding and removing zone members Refer to Resettin...

Page 89: ...r Accounts Displaying Switch Information Configuring Port Threshold Alarms Paging a Switch Setting the Date Time and Enabling NTP Client Resetting a Switch Configuring a Switch Archiving a Switch Rest...

Page 90: ...hat can manage all user accounts with the User Account Administration dialogs The Admin account can create remove or modify user accounts and change account passwords The Admin account can also view a...

Page 91: ...Click the Add Account tab to open the Add Account tab page 3 Enter an account name in the New Account Login field Account names are limited to 15 characters 4 If the account is to have the ability to...

Page 92: ...the Switch menu in the faceplate display and select User Accounts Click the Remove Account tab in the dialog to present the display shown in Figure 4 2 Select the account login name from the list of...

Page 93: ...nt login name from the list of accounts at the top of the dialog then enter the old password the new password and verify the new password in the corresponding fields Click the Change Password button A...

Page 94: ...t tab Select the account login name from the list of accounts at the top of the dialog Click the Admin authority Enabled check box to grant admin authority to the account name Click an Account Expirat...

Page 95: ...ure 4 5 Faceplate Display Switch Information The fabric updates the topology and faceplate displays by forwarding changes in status to the management workstation as they occur You can allow the fabric...

Page 96: ...re information about the Switch data window To open the Switch data window select one or more switches in the topology display or open the faceplate display and click the Switch tab below the data win...

Page 97: ...uration R_A_TOV Resource allocation timeout value E_D_TOV Error detect timeout value Interop Mode Zoning merge status If True changes to the active zone set are propagated throughout the fabric If fal...

Page 98: ...led for this switch All ports are downed when the switch temperature exceeds the Failure Temperature Warning Temperature Non configurable temperature threshold 65 Celsius above which a warning conditi...

Page 99: ...aseline to view the total count of statistics since the last time the baseline was set Click the Clear Baseline button to set the current baseline 4 2 4 Port Information Data Window The Port Informati...

Page 100: ...n the topology display and click the Active Zonesets data window tab The Configured Zonesets data window uses display conventions for expanding and contracting entries that are similar to the fabric t...

Page 101: ...ent set triggers set a sample window and enable or disable an individual alarm Figure 4 7 Port Threshold Alarm Configuration Dialog 2 Check the Enable All Port Threshold Alarms check box to enable mon...

Page 102: ...conds The sample window defines the period of time in which to count events 8 Repeat steps 3 through 7 for each alarm you want to configure or enable 9 Click the OK button to save all changes 4 4 Pagi...

Page 103: ...t Set Date Time 3 Choose one of the following Enter the year month day time and time zone in the Switch Date Time dialog then click OK The new date and time take effect immediately Click the NTP Clien...

Page 104: ...evious switch code releases is not supported To reset a switch using SANsurfer Switch Manager do the following 1 Select the switch to be reset and open the faceplate display 2 Open the Switch menu and...

Page 105: ...on steps on new or replacement switches Configuring a switch involves the following tools and properties Using the Configuration Wizard Switch Properties Advanced Switch Properties Network Properties...

Page 106: ...erties from the popup menu Use the Switch Properties dialog to change the following switch configuration parameters Symbolic Name Switch Administrative States Domain ID and Domain ID Lock Fabric Devic...

Page 107: ...changes to the configured administrative state The configured administrative state is displayed in the Switch Properties dialog The current administrative state is the state that is applied to the swi...

Page 108: ...or taking it offline then back online The principal switch will reassign the domain ID and the switch will join the fabric 4 7 2 4 Fabric Device Management Interface Fabric Device Management Interfac...

Page 109: ...standard specified in Multi Switch Broadcast for FC SW 3 T11 Presentation Number T11 02 031v0 Fabric Shortest Path First FSPF is used to set up a fabric spanning tree used in transmission of broadcas...

Page 110: ...e switch will automatically be taken offline temporarily and will be restored to its original state after the changes are completed To open the Advanced Switch Properties dialog open the Switch menu a...

Page 111: ...These should not be changed unless absolutely necessary Therefore the switch must be offline to change these values Use the Switch Properties dialog to take the switch offline Table 4 5 Timeout Value...

Page 112: ...ric 4 7 3 3 Legacy Port Address Format Legacy Address Format should be enabled only to permit interoperation with certain older non FC SW 2 compliant switches Enabling this setting under other circums...

Page 113: ...1 to change IP configuration parameters and enable remote logging After making changes click the OK button to put the new values into effect To open the Network Properties dialog select a switch in th...

Page 114: ...vals If no IP address is obtained the switch reverts to the previously config ured IP address DHCP Dynamic Host Configuration Protocol Acquires the IP configuration from a DHCP server If no satisfacto...

Page 115: ...perating system documentation for information on how to configure Remote Logging The syslog conf file on the remote host must contain an entry that specifies the name of the log file in which to save...

Page 116: ...lick the OK button to put the new values into effect To open the SNMP Properties dialog select a switch in the topology display or open the faceplate display open the Switch menu and select SNMP Prope...

Page 117: ...on the switch and the SNMP management server must be the same The default is public Trap Community Trap community password up to 32 characters that authorizes an SNMP agent to receive traps This is a...

Page 118: ...nique For example if trap 1 and trap 2 have the same address then they must have different port values Similarly if trap 1 and 2 have the same port value they must have different addresses Specifies t...

Page 119: ...operties and statistics Alarm configuration Zoning configuration This archive file can be used to restore the configuration on the same switch or on a replacement switch You can also use the archive f...

Page 120: ...on page 4 31 for more information To restore a switch do the following 1 Log in to the fabric through the switch you want to restore You cannot restore a switch over an ISL 2 Open the Switch menu in t...

Page 121: ...k Properties on page 4 25 IP Address Restores switch IP address in addition to the other network properties Switch Properties Restores all settings presented in the Switch properties dialog except the...

Page 122: ...elect the Reset Password File option in the maintenance menu Refer to Recovering a Switch in the Installation Guide for your switch for information about maintenance mode and the maintenance menu Tabl...

Page 123: ...utton to define a location for the support file or type the path in the text field 3 Click the Start button to begin the process of creating and downloading the support file to your workstation Observ...

Page 124: ...he fabric if any are complete When you need to do NDCLA hotreset to multiple switches only perform the NDCLA hotreset on one switch at a time and allow a 75 second wait before performing the NDCLA hot...

Page 125: ...ANsurfer Switch Manager prompts you to activate the new firmware using a hot non disruptive reset if possible Click the OK button to reset the switch and activate the new firmware 4 13 Displaying Hard...

Page 126: ...4 Managing Switches Displaying Hardware Status 4 38 59226 00 B S Notes...

Page 127: ...a Port Testing Ports Graphing Port Performance 5 1 Displaying Port Information Port information is available primarily in the faceplate display shown in Figure 5 1 The faceplate display data windows...

Page 128: ...port types and their meanings Table 5 1 Port Types State Description F_Port Fabric port Supports a single public device N_Port FL_Port Fabric loop port Self discovers a single device N_Port or a loop...

Page 129: ...lists the possible port speeds Table 5 2 Port Operational States State Description On Online port is active and ready to send data Ia Inactive port operational state is offline but administrative sta...

Page 130: ...tics data window and provides different ways to view detailed port information Click the down arrow to open the pull down menu Open the pull down menu and select Absolute to view the total count of st...

Page 131: ...ames Out Number of class 2 frames transmitted by this port Class 2 Words In Number of class 2 words received by this port Class 2 Words Out Number of class 2 words transmitted by this port Class 3 Fra...

Page 132: ...ed A link reset is performed after a link failure LIP AL_PD AL_PS Number of F7 AL_PS LIPs or AL_PD vendor specific resets performed LIP f7 AL_PS This LIP is used to reinitialize the loop An L_port ide...

Page 133: ...Received Number of loop initialization primitive frames received Total LIPs Transmitted Number of loop initialization primitive frames transmitted Tx Offline Sequences Number of offline primitives tra...

Page 134: ...nd will be lost on a switch reset Operational Port State The port state that is currently active This value may be different from the adminis trative port state for example due to an error condition C...

Page 135: ...up The donor group of the selected port Valid Donor Groups The number of separate groups within which extended credits may be donated and assigned Medium The transceiver type Media The transceiver typ...

Page 136: ...To open the corresponding type of Port Properties dialog select one or more ports open the Port menu and select Port Properties Figure 5 2 Port Properties Dialog The Port Properties dialog displays th...

Page 137: ...served across switch resets The current administrative state is set using the Set Port command Refer to the Set Port Command on page A 55 Table 5 7 describes the port administrative states To change p...

Page 138: ...the port speed do the following 1 Select one or more ports in the faceplate display 2 Open the Port menu and select Port Properties 3 Click the radio button that corresponds to the port speed you want...

Page 139: ...e public device N_Port FL_Port Fabric loop port Self discovers a single device N_Port or a loop of up to 126 public devices NL_Port FL_Port Fabric loop port Self discovers a single device N_Port or a...

Page 140: ...port is connected to an initiator device with a QLogic HBA For older QLogic HBAs such as the QLA2200 Device Scan must be enabled The default is Auto Refer to Device Scan on page 5 14 5 2 5 Device Scan...

Page 141: ...process For example one donor port contributes 7 credits to the pool from which a recipient draws for a total of 14 credits 7 7 This provides approximately 23 Km at 1 Gbps 14 0 6 or 11 Km at 2 Gbps 1...

Page 142: ...Testing Ports The port loopback tests verify correct port operation by sending a frame out through the loop and then verifying that the frame received matches the frame that was sent Only one port can...

Page 143: ...es not disrupt communication on the selected port This test requires that the port be online and therefore does not disrupt communication To run the internal external or online port loopback test on a...

Page 144: ...launch the SANsurfer Performance View application from the SANsurfer Switch Manager application and SANsurfer Performance View can not connect to the fabric for example if you have reached the maximu...

Page 145: ...View application from the SANsurfer Switch Manager application on Linux and Solaris platforms the fabric currently displayed in the SANsurfer Switch Manager topology display opens automatically in the...

Page 146: ...ve the current performance view file as the default performance view file Refer to Changing the Default Performance View File Encryption Key on page 5 22 for information about defining and changing th...

Page 147: ...Files In addition to the default performance view file you can save and open your own performance view files The performance view file contains the set of fabrics graphs and graphing options To save...

Page 148: ...ew Preferences To set preferences open the File menu and select Preferences to open the Preferences dialog shown in Figure 5 8 Set the following preferences and click the OK button to save the changes...

Page 149: ...t SANsurfer Performance View plots total bytes transmitted and received at a polling frequency of once per second Refer to Customizing Graphs on page 5 24 for information about changing what is plotte...

Page 150: ...ick a graph on the Window menu to bring that graph to the front 5 6 7 2 Customizing Graphs You can customize the graph polling frequency what is plotted in the graphs and the graph color scheme To set...

Page 151: ...ck box to plot data in frames second 2 Choose what data type to plot For example if you selected Show Frames Data on Graph in step 1 you can plot one or all of the following Total frames transmitted a...

Page 152: ...ns dialog click the corresponding radio button to apply changes to all graphs the currently selected graph or all new graphs 6 In the Default Graph Options dialog click the OK button to save the color...

Page 153: ...Window from the popup menu 5 6 9 Saving Graph Statistics to a File Statistics for one or all graphs can be saved to a file that can be opened with a spreadsheet application To save a graph statistics...

Page 154: ...5 Managing Ports Graphing Port Performance 5 28 59226 00 B S...

Page 155: ...section describes the following Logging On to a Switch User Accounts Working with Switch Configurations Commands A 1 Logging On to a Switch To log on to a switch using Telnet open a command line wind...

Page 156: ...Refer to Passwd Command on page A 27 for information about changing passwords A 3 Working with Switch Configurations Successful management of switches and fabrics with the command line interface depen...

Page 157: ...t list of configurations default config_10132003 To modify a switch configuration you must open an Admin session with the Admin Start command An Admin session prevents other accounts from making chang...

Page 158: ...3 2 Backing up and Restoring Switch Configurations Backing up and restoring a configuration is useful to protect your work or for use as a template in configuring other switches The Config Backup com...

Page 159: ...and the Config Restore command To upload the configuration file config_switch_169_10112003 in this case open and FTP session with account name images and password images Transfer the file in binary m...

Page 160: ...Delete keyword can be abbreviated Del The command line completion feature makes entering and repeating commands easier Table A 1 describes the command line completion keystrokes Table A 1 Command Lin...

Page 161: ...ommands Listed by Authority Level Monitoring Commands Configuration Command Help History Ping Ps Quit Show Show Config Show Log Show Perf Show Setup Uptime Whoami A 20 A 21 A 28 A 29 A 30 A 62 A 77 A...

Page 162: ...start or begin Opens the admin session end or stop Closes the admin session The Hardreset Hotreset Logout Shutdown and Reset Switch commands will also end an admin session cancel Terminates an Admin...

Page 163: ...ias can have a maximum of 2000 members A port device in member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can be 1 239 port numbers can...

Page 164: ...This keyword does not require an admin session remove alias member_list Removes the ports devices given by member_list from the alias given by alias Use a space to delimit ports devices in member_list...

Page 165: ...configuration can be active at a time backup Creates a file named configdata which contains the system configuration information To download this file open an FTP session log in with account name pas...

Page 166: ...ame If you omit config_name the value for config_name you chose for the most recent Config Edit command is used config_name can be up to 31 characters excluding semicolon and comma The switch supports...

Page 167: ...igdata from the workstation to the switch and then restore the configuration ftp symbolic_name or ip_address user images password images ftp bin ftp put configdata ftp quit SANbox admin start SANbox a...

Page 168: ...to send it to a remote host This file is useful to technical support personnel for troubleshooting switch problems Use this command when directed by your authorized maintenance provider The command p...

Page 169: ...ersion wu 2 6 1 18 ready 331 Password required for johndoe Password xxxxxxx 230 User johndoe logged in cd bin support 250 CWD command successful lcd itasca conf images Local directory now itasca conf...

Page 170: ...ol NTP must be disabled to set the time with the Date command Refer to the Set Setup Command on page A 57 System keyword for information about NTP Authority Admin session except to display the date Sy...

Page 171: ...ture Command Displays the license key feature log Authority None Syntax feature add license_key log Keywords add license_key This keyword does not apply to this switch because there are no licensable...

Page 172: ...ll command SANbox admin firmware install Warning Installing new firmware requires a switch reset Continuing with this action will terminate all management sessions including any Telnet sessions When t...

Page 173: ...tivates the pending firmware and clears the alarm log To save the alarm log before resetting refer to the Set Log Command on page A 51 Authority Admin session Syntax hardreset Notes To reset the switc...

Page 174: ...mand all Displays a list of all available commands including command variations Examples The following is an example of the Help Config command SANbox help config config CONFIG_OPTIONS The config comm...

Page 175: ...hes command_string Enter line number to re execute the corresponding command from the History display Enter partial command string to re execute a command that matches the command string Enter to re e...

Page 176: ...ng to re initialize attached devices under the following conditions The current firmware version is a 5 0 x version that precedes the upgrade version No changes are being made to switches in the fabri...

Page 177: ...password to access the FTP server the system will prompt you for it install Downloads firmware from a remote host to the switch installs the firmware then resets the switch to activate the firmware Th...

Page 178: ...copy the firmware image file on the switch ftp bin ftp put filename 6 Wait for the transfer to complete then close the FTP session xxxxx bytes sent in xx secs ftp quit 7 Establish communications with...

Page 179: ...th this action will terminate all management sessions including any Telnet sessions When the firmware activation is complete you may log in to the switch again Do you want to continue y n y Press q an...

Page 180: ...and Reinitializes the specified loop port Authority Admin session Syntax lip port_number Keywords port_number The number of the port to be reinitialized Ports are numbered beginning with 0 Examples Th...

Page 181: ...name The user account name To change the password for an account name other than your own you must open an admin session with the account name Admin If you omit account_name you will be prompted to ch...

Page 182: ...eywords ip_address The IP address of the switch to query Examples The following is an example of a successful Ping command SANbox ping 10 20 11 57 Ping command issued Waiting for response SANbox Respo...

Page 183: ...18 35 ds 342 327 0 2 00 11 29 3 01 18 35 mgmtApp 343 327 0 0 00 00 04 3 01 18 35 fc2 344 327 0 0 00 02 16 3 01 18 35 nserver 345 327 0 0 00 02 44 3 01 18 35 mserver 346 327 0 8 00 35 12 3 01 18 35 uti...

Page 184: ...A Command Line Interface Quit Command A 30 59226 00 B S Quit Command Closes the Telnet session Authority None Syntax quit exit or logout Notes You can also enter Control D to close the Telnet session...

Page 185: ...vate the configuration for the changes to take effect Refer to Table A 3 through Table A 6 for switch port and port threshold alarm configuration default values factory Resets switch configuration por...

Page 186: ...page A 22 system Resets the system configuration settings to the factory default values Refer to Table A 8 for system configuration default values zoning Clears the zoning database and deactivates the...

Page 187: ...Default Admin State Online Link Speed Auto Port Type GL Symbolic Name Port n where n is the port number ALFairness False DeviceScanEnabled True ForceOfflineRSCN False ARB_FF False InteropCredit 0 ExtC...

Page 188: ...SampleWindow True 25 1 10 DecodeErrorsMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 25 0 10 ISLMonitoringEnabled RisingTrigger FallingTrigger SampleWindow True 2 0 10 LoginMonitorin...

Page 189: ...able A 7 SNMP Configuration Defaults Parameter Default SNMPEnabled True Contact syscontact undefined Location sysLocation undefined Description SANbox 1400 FC Switch Trap 1 5 Address Trap 1 10 0 0 254...

Page 190: ...twork Discovery Static Ethernet Network IP Address 10 0 0 1 Ethernet Network IP Mask 255 0 0 0 Ethernet Gateway Address 10 0 0 254 Admin Timeout 30 minutes InactivityTimeout 0 LocalLogEnabled True Rem...

Page 191: ...eam or clears the alarm log option can be one of the following clear Clears the alarm log history This value requires an Admin session on Enables the display of alarms in the session output stream off...

Page 192: ...ing Active List off Allows continuous display of information without a break port option Sets port state and speed for the specified port The previous Set Config Port settings are restored after a swi...

Page 193: ...orkstation The default is Universal Time UTC also known as Greenwich Mean Time GMT This keyword prompts you to choose a region then a subregion to specify the time zone Examples The following examples...

Page 194: ...y to accept the current value shown in brackets Enter q to end the configuration for one port or qq to end the configuration for all ports Table A 9 describes the port parameters ports port_number Ini...

Page 195: ...rrupted If enabled the RSCN message is delayed for 200 ms for locally attached devices and 400 ms for devices connected through other switches The default is False This param eter is ignored if IOStre...

Page 196: ...e Sequence bundling This parameter appears only if AutoPerfTuning is False Prevents True or allows False the interleaving of frames in a sequence The default is False Enabling MFSEnable disables LCFEn...

Page 197: ...SCN mes sages under the following conditions 1 The port is connected to an initiator device with a QLogic HBA 2 The DeviceScanEnable parameter is enabled Auto is the default PDISCPingEnable Enables Tr...

Page 198: ...eout Value The number of millisec onds a port is to wait for errors to clear The default is 2000 PrincipalPriority The priority used in the FC SW 2 principal switch selection algorithm 1 is high 255 i...

Page 199: ...shold Parameters Parameter Description Threshold Monitoring Enabled Master enable disable parameter for all events Enables True or disables False the generation of all enabled event alarms The default...

Page 200: ...ent memory Refer to InteropMode on page A 44 The default is True Disabling the Autosave parameter can be useful to prevent the propagation of zoning information when experimenting with dif ferent zoni...

Page 201: ...s A Auto Auto PortType GL G F FL Donor GL SymPortName string max 32 chars Port1 ALFairness True False False DeviceScanEnable True False True ForceOfflineRSCN True False False ARB_FF True False False I...

Page 202: ...efore reaching the end of the list press q or Q and the ENTER key to do so AdminState 1 Online 2 Offline 3 Diagnostics Online BroadcastEnable True False False InbandEnabled True False False FDMIEnable...

Page 203: ...imal value 1 1000 25 FallingTrigger decimal value 0 1000 0 SampleWindow decimal value 1 1000 sec 10 ISLMonitoringEnabled True False True RisingTrigger decimal value 1 1000 2 FallingTrigger decimal val...

Page 204: ...ue or simply press the ENTER key to accept the current value If you wish to terminate this process before reaching the end of the list press q or Q and the ENTER key to do so InteropAutoSave True Fals...

Page 205: ...l log entries and stores the result in new file named logfile that is maintained in switch memory where it can be downloaded using FTP To download logfile open an FTP session log in with account name...

Page 206: ...automatically display on the screen according to the event severity levels given by filter filter can be one of the following values Critical Critical severity level events The critical level describe...

Page 207: ...ibes events that are generally not disruptive to the administration or operation of the fabric but are more important than the informative level events Info Monitors informative warning and critical e...

Page 208: ...and start Starts the logging of events based on the Port Component and Level keywords assigned to the current configuration The logging continues until you enter the Set Log Stop command stop Stops lo...

Page 209: ...d beginning with 0 bypass alpa Sends a Loop Port Bypass LPB to a specific Arbitrated Loop Physical Address ALPA or to all ALPAs on the arbitrated loop alpa can be a specific ALPA or the keyword ALL to...

Page 210: ...the port online This activates and prepares the port to send data Offline Places the port offline This prevents the port from receiving signal and accepting a device login Diagnostics Prepares the por...

Page 211: ...events The name can be up to 64 characters excluding semicolon and comma The default is undefined Location Specifies the name of the switch location The name can be up to 64 characters excluding semi...

Page 212: ...te community password can be up to 32 characters excluding semicolon and comma The default is private TrapCommunity Trap community password that authorizes an SNMP agent to receive traps This is a wri...

Page 213: ...lt is False RemoteLogHostAddress The IP address of the host that will receive the switch event log information if remote logging is enabled The default is 10 0 0 254 NTPClientEnabled Enables True or d...

Page 214: ...ee allowed options above warning Trap1Version 1 2 2 Trap1Enabled True False False Trap2Address dot notated IP Address 0 0 0 0 Trap2Port decimal value 162 Trap2Severity see allowed options above warnin...

Page 215: ...d the ENTER key to do so Eth0NetworkDiscovery 1 Static 2 Bootp 3 Dhcp 4 Rarp Static Eth0NetworkAddress dot notated IP Address 10 0 0 1 Eth0NetworkMask dot notated IP Address 255 255 255 0 Eth0GatewayA...

Page 216: ...chassis config option domains donor fabric fdmi port_wwn interface log option lsdb mem count ns option pagebreak perf option port port_number post log setup option steering domain_id support switch ti...

Page 217: ...nfig option Displays switch port and zoning configuration attributes Refer to the Show Config Command on page A 77 domains Displays list of each domain and its worldwide name in the fabric donor Displ...

Page 218: ...rmation for all switches and ports domain_id Displays name server information for the switch given by domain_id domain_id is a switch domain ID port_id Displays name server information for the port gi...

Page 219: ...port ClassXToss Number of times an SOFi3 or SOFn3 frame is tossed from TBUF DecodeError Number of decode errors detected EpConnects Number of times an E_Port connected through ISL negotia tion FBusy...

Page 220: ...ied by FC AL 2 LossOfSync Number of synchronization losses 100 ms detected by this port A loss of synchronization is detected by receipt of an invalid transmission word PrimSeqErrors Primitive sequenc...

Page 221: ...and on page A 87 steering domain_id Displays the routes that data takes to the switch given by domain_id If you omit domain_id the system displays routes for all switches in the fabric TotalTxFrames T...

Page 222: ...ev Settings Domains Donor Fabric Log Log Archive Log Settings Lsdb Mem Ns Perf Port Setup Mfg Setup Snmp Setup System Steering Switch Topology Users Uptime User Accounts Whoami Zoneset Active List Zon...

Page 223: ...rsion build date Firmware image version and build date that is pending This image will become active at the next reset or power cycle ActiveConfiguration Name of the switch configuration that is in us...

Page 224: ...how domains Principal switch is remote 10 00 00 60 69 50 0b 6c Upstream Principal ISL is 1 Domain ID List Domain 97 0x61 WWN 10 00 00 c0 dd 00 71 ed Domain 103 0x67 WWN 10 00 00 60 69 50 0b 6c The fol...

Page 225: ...wareVersion 03 02 13 OperatingSystem SunOS 5 8 MaximumCTPayload 2040 NumberOfPorts 1 Port 21 01 00 e0 8b 27 aa bc SupportedFC4Types FCP SupportedSpeed 2Gb s CurrentSpeed 2Gb s MaximumFrameSize 2048 OS...

Page 226: ...4Type FCP FC4Desc NULL The following is an example of the Show Interface command SANbox show interface eth0 Link encap Ethernet HWaddr 00 C0 DD 00 BD ED inet addr 10 20 68 107 Bcast 10 20 68 255 Mask...

Page 227: ...mbolicName Port8 MaxCredit 8 SyncStatus SyncAcquired MediaSpeeds 1Gb s 2Gb s 4Gb s XmitterEnabled True ALInit 5 LIP_F8_AL_PS 0 ALInitError 0 LIP_F8_F7 0 BadFrames 0 LinkFailures 2 Class2FramesIn 0 Log...

Page 228: ...x 0 2 day month date time year PendingImageVersion build date Vx x x 0 17 day month date time year ActiveConfiguration default AdminState Online AdminModeActive False BeaconOnStatus False OperationalS...

Page 229: ...tID 650100 PortWWN 20 01 00 c0 dd 00 91 11 PortType F Remote Link Information Device 0 NodeWWN 50 80 02 00 00 06 d5 38 PortType NL Description NULL IPAddress 0 0 0 0 Device 1 NodeWWN 20 00 00 20 37 2b...

Page 230: ...Interface SHell CLISH SystemDescription SANbox 1400 FC Switch Eth0NetworkAddress 10 20 116 37 use set setup system to update MACAddress 00 c0 dd 07 02 17 WorldWideName 10 00 00 c0 dd 07 02 17 Chassis...

Page 231: ...ort_number switch threshold zoning Keywords port port_number Displays configuration parameters for the port number given by port_number Ports are numbered beginning with 0 If port_number is omitted al...

Page 232: ...False MFSEnabled True MSEnabled True NoClose False IOStreamGuard Disabled VIEnabled False PDISCPingEnable True The following is an example of the Show Config Switch command SANbox show config switch...

Page 233: ...onitoringEnabled True RisingTrigger 25 FallingTrigger 1 SampleWindow 10 DecodeErrorsMonitoringEnabled True RisingTrigger 25 FallingTrigger 0 SampleWindow 10 ISLMonitoringEnabled True RisingTrigger 2 F...

Page 234: ...ommand A 80 59226 00 B S The following is an example of the Show Config Zoning command SANbox show config zoning Configuration Name default Zoning Configuration Information InteropAutoSave True Defaul...

Page 235: ...of events component display filter level options port settings Keywords number of events Specifies the number of the most recent events to display from the event log number of events must be a positi...

Page 236: ...o the component or severity level filter given by filter filter can be one of the following Info Displays all informative events Warning Displays all warning events Critical Displays all critical even...

Page 237: ...ettings Displays the current filter settings for component severity level port and display level This command is equivalent to executing the following commands separately Show Log Component Show Log L...

Page 238: ...330 day month date time year I Eport Port 0 8 Processing EFP oxid 0x8 331 day month date time year I Eport Port 0 8 Eport State E_A2_IDLE 332 day month date time year I Eport Port 0 8 EFP WWN 0x10000...

Page 239: ...rmance data in bytes second received for all ports Type q and press the Enter key to stop the display outbyte Displays continuous performance data in bytes second transmitted for all ports Type q and...

Page 240: ...136M 58K 136M 68K 1K 70K 8 7K 136M 136M 245 68K 68K 9 58K 0 58K 1K 0 1K The following is an example of the Show Perf Byte command SANbox show perf byte Displaying bytes sec data Press any key to stop...

Page 241: ...tings system Displays the current system settings Examples The following is an example of the Show Setup Mfg command SANbox show setup mfg Manufacturing Information BrandName QLogic Corporation BuildD...

Page 242: ...rt 162 Trap1Severity warning Trap1Version 2 Trap1Enabled False Trap2Address 0 0 0 0 Trap2Port 162 Trap2Severity warning Trap2Version 2 Trap2Enabled False Trap3Address 0 0 0 0 Trap3Port 162 Trap3Severi...

Page 243: ...tup system System Information Eth0NetworkDiscovery Static Eth0NetworkAddress 10 20 11 32 Eth0NetworkMask 255 255 252 0 Eth0GatewayAddress 10 20 8 254 AdminTimeout 30 InactivityTimeout 0 LocalLogEnable...

Page 244: ...tch at convenient points and closes the Telnet session Always power cycle the switch after entering this command Authority Admin session Syntax shutdown Notes Always use this command to perform an ord...

Page 245: ...al Tests the SerDes for all port speeds independent of the capabilities of the transceiver This is the default The port must be in diagnostics mode to perform this test external Tests both the SerDes...

Page 246: ...TestLength parameter is the number of frames sent the FrameSize 256 byte maximum in some cases parameter is the number of bytes in each frame and the DataPattern parameter is the pattern in the payloa...

Page 247: ...ached to the port can handle the test parameters SANbox admin test port x online A list of attributes with formatting and current values will follow Enter a new value or simply press the ENTER key to...

Page 248: ...last reset and reset method A hot reset or non disruptive firmware activation does not reset the elapsed up time reported by this command Authority None Syntax uptime Examples The following is an exa...

Page 249: ...swords must be 4 20 characters Admin authority grants permission to use the Admin command to open an admin session from which all commands can be entered Without Admin authority you are limited to vie...

Page 250: ...owing is an example of the User Add command SANbox admin user add Press q and the ENTER key to abort this command account name 1 15 chars user1 account password 4 20 chars please confirm account passw...

Page 251: ...y The following is an example of the User List command SANbox admin user list User Ethernet Addr Port Logged in Since admin OB session1 10 20 68 108 1031 day month date time year admin OB session2 10...

Page 252: ...Command Displays the account name session number and switch domain ID for the Telnet session Authority None Syntax whoami Examples The following is an example of the Whoami command SANbox whoami User...

Page 253: ...liases and ports devices in member_list A zone can have a maximum of 2000 members member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can...

Page 254: ...ember_list member_list can have any of the following formats Domain ID and port number pair Domain ID Port Number Domain IDs can be 1 239 port numbers can be 0 255 6 character hexadecimal device Fibre...

Page 255: ...23bd31 zone_set_1 wwn_221416 zone_set_1 wwn_2215c3 zone_set_1 wwn_0160ed zone_set_1 wwn_c001b0 zone_set_1 wwn_401248 zone_set_1 wwn_02402f zone_set_1 wwn_22412f zone_set_1 The following is an example...

Page 256: ...A Command Line Interface Zone Command A 102 59226 00 B S The following is an example of the Zone Zonesets command SANbox zone zonesets zone1 Current List of ZoneSets for Zone zone1 zone_set_1...

Page 257: ...ew zones zone_set Keywords activate zone_set Activates the zone set given by zone_set This keyword deactivates the active zone set Close the Zoning Edit session before using this keyword active Displa...

Page 258: ...e removed until the zone set has been deactivated rename zone_set_old zone_set_new Renames the zone set given by zone_set_old to the name given by zone_set_new You can rename the active zone set zones...

Page 259: ...A Command Line Interface Zoneset Command 59226 00 B A 105 A The following is an example of the Zoneset Zones command SANbox zoneset zones ssss Current List of Zones for ZoneSet ssss zone1 zone2 zone3...

Page 260: ...r the active zone set including component zones and zone members This keyword does not require an Admin session cancel Closes the current Zoning Edit session Any unsaved changes are lost clear Clears...

Page 261: ...n session list Lists all fabric zoning definitions This keyword does not require an Admin session restore Reverts the changes to the zoning database that have been made during the current Zoning Edit...

Page 262: ...be activated to implement any changes This does not apply if you entered the Zoning Clear command during the Zoning Edit session Examples The following is an example of the Zoning Edit command SANbox...

Page 263: ...256 6 MaxZones 2000 17 MaxAliases 2500 1 MaxTotalMembers 10000 166 MaxZonesInZoneSets 2000 19 MaxMembersPerZone 2000 10 D_1_JBOD_1 23 D_1_Photons 9 D_2_JBOD1 16 D_2_NewJBOD_2 5 E1JBOD1 5 E2JBOD2 3 Li...

Page 264: ...4 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 23 bd 31 wwn_221416 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2 18 d2 10 00 00 00 c9 22 14 16 wwn_2215c3 50 06 04 82 bf d2 18 c2 50 06 04 82 bf d2...

Page 265: ...A Command Line Interface Zoning Command 59226 00 B A 111 A...

Page 266: ...A Command Line Interface Zoning Command A 112 59226 00 B S Notes...

Page 267: ...A named set of ports or devices An alias is not a zone and can not have a zone or another alias as a member AL_PA Arbitrated Loop Physical Address Arbitrated Loop A Fibre Channel topology where ports...

Page 268: ...name associated with the file that contains user list data for the fabric Fabric Port An F_Port Fabric View File A file containing a set of fabrics that were opened and saved during a previous SANsurf...

Page 269: ...Workstation PC workstation that manages the fabric through the fabric management switch Mesh Topology A fabric in which each chassis has at least one port directly connected to each other chassis in...

Page 270: ...initiator device User Account An object stored on a switch that consists of an account name password authority level and expiration date VCCI Voluntary Control Council for Interference World Wide Nam...

Page 271: ...3 38 rename A 10 Alias command A 9 Arbitrated Loop Physical Address A 55 archive configuration 4 31 authentication trap 4 29 authority A 7 auto save default fabric view file 2 18 graphing options 5 22...

Page 272: ...Configuration Protocol 4 26 E E_Port isolation 3 39 4 20 encryption key 2 17 5 22 Error Detect Timeout 4 23 event browser filter 3 13 preference 2 18 sort 3 14 event logging by component A 51 A 81 by...

Page 273: ...h type 5 26 graph type 5 26 graphic window 2 25 H hard reset 4 16 Hardreset command A 19 hardware status 4 37 Heartbeat LED 4 37 help 2 19 Help command A 20 History command A 21 host bus adapter A 63...

Page 274: ...col client 4 15 A 59 server A 59 nickname create 3 18 delete 3 19 description 3 18 edit 3 19 export to file 3 19 import file 3 20 node to node test 5 17 non disruptive activation A 22 Non Disruptive C...

Page 275: ...preferences Performance View 5 22 SANsurfer Switch Manager 2 18 principal switch 4 20 processor 2 2 properties network 4 25 port 5 10 Simple Network Management Protocol 4 28 switch 4 18 Ps command A...

Page 276: ...ing A 67 subnet mask address 4 26 support file 4 35 switch add 3 7 administrative state 4 19 A 38 advanced properties 4 22 configuration 4 17 A 43 configuration display A 77 delete 3 7 displaying info...

Page 277: ...A 95 V version 2 19 Virtual Interface preference routing A 42 W web applet enable A 59 Whoami command A 98 wizard configuration 4 17 extended credit 5 15 working directory 2 18 5 22 status indicator 2...

Page 278: ...ember zone 3 32 A 104 discard inactive 3 29 display A 104 display active A 103 display members A 104 display zones A 100 management 3 31 orphan 3 22 remove 3 33 rename 3 36 A 104 tree 3 26 Zoneset com...

Reviews: