1. Disconcert the Linkarm from the Moving Arm:
a. Remove the #2 Phillips screw and the Outer Linkarm cover. Retain part(s) and/or
fastener(s) for installation.
b. Loosen the 9/16" Linkarm hex bolt and remove the Linkarm from the Moving Arm.
Retain part(s) and/or fastener(s) for installation.
c. Remove the Inner Linkarm cover from the Moving Arm. Retain part(s) and/or
fastener(s) for installation.
2. Remove the Linkarm from the Moving Stairarm:
a. Remove the #2 Phillips screw fastener and remove the Outer Linkarm Cover.
Retain part(s) and/or fastener(s) for installation.
b. Remove the 9/16" hex head screw and remove the Linkarm from the Stairarm
weldment - Linkarm bracket and carefully lay onto the floor.
c. Remove the Inner Linkarm cover, and Linkarm Transition cover from the Stair-
arm weldment - Linkarm bracket. Retain hardware and fastener for installation.
3. Loosen the top half of the side cover from the front tower weldment:
a. Remove the front upper corner and the middle front #3 Phillips side cover weld-
ment screws.
b. Then remove the two #2 Phillips screws and the Upper Pivot Anchor bracket.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 158
6 Replacement Procedures
Linkarm Replacement