9. Use a 1/2" socket to remove the Generator/Eddy Brake assembly lower carriage bolt.
Then slide the Generator/Eddy Brake assembly downward and remove the upper car-
riage bolt. Remove the Generator/Eddy Brake assembly from the Step-up Pul-
ley/Tensioner assembly. Retain part(s) and/or fastener(s) for installation.
TIP
: Remove the lower carriage bolt fastener first and then the upper. The upper bolt
cannot be removed while the lower bolt is installed.
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 99
6 Replacement Procedures
Generator/Eddy Brake assembly Replacement