SYSTEM TESTS
MENU
TEST DESCRIPTION
l
A/D
1
: Lift potentiometer analog to digital voltage value.
l
Glitches: number of sticking lift motion.
l
Volts (DC): lift motor voltage.
USB Test
menu:
System Tests
>
USB Test
List the active USB ports.
Touchscreen Test
menu:
System Tests
>
Touchscreen Test
Verify touchscreen display.
Touchscreen Cal-
ibration
menu:
System Tests
>
Touchscreen Calibration
Calibrates touchscreen finger press operation.
Backlight Test
menu:
System Tests
>
Backlight Test
Tests the display backlight performance.
RGB Test
menu:
System Tests
>
RGB Test
Tests the display color performance.
Numeric Backlight
Test
menu:
System Tests
>
Numeric Backlight Test
Tests the movement controls LCD numeric displays backlight
brightness level.
Numeric Display
Test
menu:
System Tests
>
Numeric Display Test
Tests the movement controls LCD numeric displays.
Heart Rate Test
menu:
System Tests
>
Heart Rate Test
Tests the handlebar unfiltered, filtered, and pulse heart rate. Grasp
the grips to test the hand held heart rate. Use a Polar heart rate sim-
ulator to test the wireless heart rate. Press the back button to exit
this test.
(1) Not included on elliptical or treadmill products that do not have the maintenance and
ASL features. Not included on the EFX600 series, the TRM600 series, or the TRM800-10
(TRM10/GEN06) series products.
Club Settings (5651565)
Service Access Code: 5651565
1
analog to digital converter
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 42
4 Standard Service Menus
Touchscreen Console Standard Service Menus