1. Remove the Top Lift cover, see
.
2. Disconcert the Linkarm from the Moving Arm:
a. Remove the #2 Phillips screw and the Outer Linkarm cover. Retain part(s) and/or
fastener(s) for installation.
b. Loosen the 9/16" Linkarm hex bolt and remove the Linkarm from the Moving Arm.
Retain part(s) and/or fastener(s) for installation.
c. Remove the Inner Linkarm cover from the Moving Arm. Retain part(s) and/or
fastener(s) for installation.
3. Remove the Moving Arm:
a. Remove the 3/16" hex key pivot shaft
outer
Nylock set screw. Do not loosen and
then retighten the set screw, this will damage the Nylock patch. Discard and do
not reuse the Nylock set screw.
b. Then remove the 3/16" hex key pivot shaft
inner
set screw and gently pull the
Moving Arm outward and over the side cover to remove. Discard the Nylock set
screw.
CAUTION
: Do not reuse the
inner
or
outer
Nylock patch set screws for installation.
Either removing or loosening the Nylock set screw will compromise the integrity of
the Nylock patch. Discard and order new set screws for installation (see
, bubble # 252).
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 144
6 Replacement Procedures
Moving Arms Replacement