Access
Hardware Validation (51765761)
>
ACTIVE STATUS LIGHT
> current ASL state.
P62, P80, and P82 consoles:
Access
Club Settings
(5651565) >
Maintenance
menu >
ACTIVE STATUS LIGHT
> cur-
rent ASL state.
Viewing the ASL maintenance counter remaining miles (or hours)
P10, P30, P30i and P31 consoles:
Access
Information Display (65)
>
MAINT COUNTER
: remaining miles (or hours) to zero.
P62, P80, and P82 consoles:
Access
Service Software
(51765761) >
Maintenance
menu >
Next Maintenance Due
The maintenance counter shows the remaining miles (or hours) until the machine main-
tenance is due. Reaching zero triggers the ASL pulsing blue "maintenance due" state.
Clearing the Blue Pulsing ASL State (Maintenance Counter reset)
Resetting the maintenance counter clears the blue pulsing ASL state and sets the ASL state to
solid blue. The maintenance counter is also reset to the default value (treadmills reset to 1000
miles, ellipticals reset to 250 Hrs).
P10, P30, P30i and P31 consoles:
1. Access
Information Display (65).
2. Scroll to
MAINT COUNTER > OK.
3. Press and hold down the
QUICKSTART
key (on the P30i, press down the
START
key) for 3 secs or more until the maintenance counter is reset. The "HOLD TO RESET
MAINTENANCE COUNTER" message will show and the maintenance counter is reset
to the default setting. The ASL state is reset to the blue solid state
P62, P80, and P82 consoles:
1. Access
Service Settings
(51765761) >
Maintenance
menu.
2. Select
Next Maintenance Due
>
Reset.
Clearing the Yellow & Yellow Pulsing ASL states
An ASL pulsing yellow state is triggered when an error code event occurs and is logged. To
clear a pulsing yellow state, the error condition causing the ASL pulsing yellow must first be
resolved either manually or the machine may resolve and self-clear the issue. A manually or
machine self-cleared error code will change the ASL state from pulsing yellow to the solid
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.