Programming the System
63
Hunter-Pro Series & Captain 8 Installation Guide
The following table lists the output types that have timers and their default times.
Output type
Time (sec.)
Ext. Siren triggered
240
Int. Siren triggered
240
Burglary alarm
240
Anti Mask alarm
240
Special Burglary 1 alarm
240
Special Burglary 2 alarm
240
Smoke alarm
240
Fire alarm
240
Special Fire alarm
240
Panic alarm
240
Silent Panic alarm
240
Hold Up alarm
240
Medical alarm
240
Tamper alarm
240
Mains Fault
9999
Low Battery
9999
Phone Failure
9999
Zone Tamper
9999
Zone Bypass
9999
GSM Fault
9999
Communication Fault
9999
Tag Activation
240
Door code entered
5
Wireless Remote
5
Test executed
5
Audio Device triggered
60
Remote control*
60
Zone Open Hold T**
0 (min.)
* This output type is triggered when a physical output is activated by telephone.
** This output type is triggered when the alarm system is disarmed and the last open zone is
closed. When count down expires the assigned physical output can be used for energy
saving - turning off the lights, for example.
6.7.3
AC report delay
Set a time (in minutes, max. 250) to delay AC fault reports. The default is 15 min.
6.7.4
Phone report delay
Set a time (in minutes) to delay reporting on telephone line faults. Note that if the parameter
“No Dia. tone chck” (see section 6.5.4, on page 59) is disabled, this parameter is negligible.
If the telephone line is usually clear, do not set a delay time.
6.7.5
Burglary report delay
Set a time in seconds (default is zero) to delay reporting on violation of 24-hour zones, if
occurred during the entry delay. The sirens will onetheless sound the alarm. This delay is valid
to all the burglary alarm types. If the panel is disarmed before coundown expires, the event
will not be reported.
Summary of Contents for Hunter-Pro 8144
Page 111: ...Appendix D CAPTAIN 8 Factory Defaults 111 Hunter Pro Series Captain 8 Installation Guide...
Page 112: ...Appendix D CAPTAIN 8 Factory Defaults 112 Hunter Pro Series Captain 8 Installation Guide...
Page 113: ...Appendix D CAPTAIN 8 Factory Defaults 113 Hunter Pro Series Captain 8 Installation Guide...
Page 114: ...Appendix D CAPTAIN 8 Factory Defaults 114 Hunter Pro Series Captain 8 Installation Guide...