Programming the System
69
Hunter-Pro Series & Captain 8 Installation Guide
[NEXT]
Output type
The event that triggers it
X31
Wireless Remote
Pressing the [*] button in a remote control to trigger an
output
X32
Test
Performing a test
X33
Not In Use
-
X34
Not In Use
-
X35
Remote Control
Activating an output by telephone
Not in use in Captain 8
X36
Not In Use
-
X37
Station ACK
This output type is triggered upon receiving an ACK from
the Monitoring Station
The assigned output is triggered for 20 sec. (not
programmable)
X38
Chime follower
Opening a “Chime” zone. This can be used for a second
indication, e.g., speaker, another buzzer, etc.
[BACK]
net4pro Comm
FLT
The net4pro card failling to communicate with the
Monitoring station (including retries). The allocated
output will be triggered for 5 sec. (not programmable)
6.10.3
Output’s partitions
Allocate this output to partition/s, i.e., set which partitions would be enabled to trigger this
output. There are 16 available partitions in HUNTER-PRO Series and 4 in Captain 8.
6.10.4
Polarity and activation while disarmed
Set the polarity of the output and whether it can be triggered while the panel is disarmed.
Char. Parameter
When set to “+”
the o
utput will be…
P
Polarity
<+=Pos.
(+): constantly tripped and disconnected when triggered
(-): tripped when and for as long as it is triggered
D
Active in
Disarm
(+): activated while the panel is disarmed (Day);
(-): deactivated while the panel is disarmed; can be used
to prevent the external siren from sounding, for example.
6.10.5
The "Ext. Siren" and "Int. Siren" outputs (Hunter-Pro only)
In Captain 8 there is only one SIREN output
The external and internal onboard siren outputs supply high current and can trigger bells &
horns. The ”Ext. Siren” output cannot be triggered separately from the “Int. Siren” output. As
a result, the sirens can be activated in one of 2 options:
Triggering both the internal and the external sirens;
Triggering the internal siren only
It is recommended to use the “External Siren” output type to trigger the “Ext. Siren”
output and the “Internal Siren” output type to trigger the “Int. Siren” output.
Summary of Contents for Hunter-Pro 8144
Page 111: ...Appendix D CAPTAIN 8 Factory Defaults 111 Hunter Pro Series Captain 8 Installation Guide...
Page 112: ...Appendix D CAPTAIN 8 Factory Defaults 112 Hunter Pro Series Captain 8 Installation Guide...
Page 113: ...Appendix D CAPTAIN 8 Factory Defaults 113 Hunter Pro Series Captain 8 Installation Guide...
Page 114: ...Appendix D CAPTAIN 8 Factory Defaults 114 Hunter Pro Series Captain 8 Installation Guide...
Page 115: ...Appendix D CAPTAIN 8 Factory Defaults 115 Hunter Pro Series Captain 8 Installation Guide...