12
HUNTER-PRO Series
Hunter-Pro Series & Captain 8 Installation Guide
2.3
Battery jump-start
Starting PCB version 3610100 Rev. E. of the Hunter-Pro, if the backup Battery’s voltage drops
under 65.0V for 30 minutes (during AC fault), the control panel disconnects it to prevent full
battery discharge. This feature extends the battery life cycle.
Because of this, the control panel cannot be powered up using only the battery, and must be
connected to AC voltage first.
When AC voltage is not available, do the following:
a)
Connect the control panel to the Battery.
b)
Momentarily connect the Battery’s (-) terminal to the control panel’s (-) terminal.
c)
The control panel will now power up.
Diagram 2.
Battery jump-start
KEYPAD
TRANSMITTER
A
C
JP1
JP2
Z1
Z2
Z3
Z4
-
+
Z7
Z O N E S
Z5
Z6
BATT
(-)
(+)
Hunter-pro
)
-
(
Short wire
Battery