Appendix C: HUNTER-PRO Series Factory Defaults
104
Hunter-Pro Series & Captain 8 Installation Guide
Zone Types & Responses
Type / Response
Sens.
Siren
Ext.
Siren
No Daytime
CMS
Different
Siren Tone
Auto
Bypass
Audio
Device
Burglary
8
+
+
-
-
-
-
Panic (*+#)
8
+
+
-
-
-
-
Fire
8
+
+
-
-
-
-
Duress
8
-
-
-
-
-
-
Medical
8
+
+
-
-
-
-
Anti Mask
8
+
+
-
-
-
-
Special Burglary 1
8
+
+
-
-
-
-
Special Burglary 2
8
+
+
-
-
-
-
Silent Panic
8
-
-
-
-
-
-
Special Fire
8
+
+
-
+
-
-
Zone Partitioning
Part./Zones-> Partition Name Zone 1-16
1-16
Partition 1
+
Communication
Tel. Line Connected
+
Disarm After Alarm
-
Bypass Dial Tone
-
Ext. Line Access
Line Test In ON
-
Number of Rings
10
Line Test In OFF
-
Not Used
8
Tone Dialing
+
Wait Phone for Ack (sec)
20
Answering Machine
+
Kissoff delay
0
Voice Unit
-
Auto Test Time (HH:MM)
00:00
Dis. Download
+
Phone interval Test (hrs)
24
Dis. Remote Disarm
+
ID Account Addition
0
Pre-Alarm
-
Phone Primary
+
Test report in OFF
+
GSM Primary
-
Split Account Number
-
Net Primary
-
GSM-200 Se PIMAnet IP
GSM-200 TX Installed
-
Use Radio Account
-
Auto Test
-
GPRS Encryption
-
SMS Backup
-
Wait For Ack (sec)
30
GSM First Mode (CMS 1)
Voice
GSM Second Mode (CMS 2)
Voice
GPRS Test Interval (min, sec)
5
0
Station 1 Port
10001
Station 2 Port
10001
GPRS Station 1 IP
000.000.000.000
GPRS Station 2 IP
000.000.000.000
Cellular Operator No.
1
Summary of Contents for Hunter-Pro 8144
Page 111: ...Appendix D CAPTAIN 8 Factory Defaults 111 Hunter Pro Series Captain 8 Installation Guide...
Page 112: ...Appendix D CAPTAIN 8 Factory Defaults 112 Hunter Pro Series Captain 8 Installation Guide...
Page 113: ...Appendix D CAPTAIN 8 Factory Defaults 113 Hunter Pro Series Captain 8 Installation Guide...
Page 114: ...Appendix D CAPTAIN 8 Factory Defaults 114 Hunter Pro Series Captain 8 Installation Guide...
Page 115: ...Appendix D CAPTAIN 8 Factory Defaults 115 Hunter Pro Series Captain 8 Installation Guide...