Pin
Description
©
PHYTEC Messtechnik GmbH 2016 L-808e_2
11
Pin #
Signal
ST
Voltage Domain
Description
A37
X_CSI1_DATA01 I
VDD_3V3_LOGIC
IPU2_CSI1 data 1
A38
X_CSI1_DATA00
I
VDD_3V3_LOGIC
IPU2_CSI1 data 0
A39
X_CSI1_VSYNC
I
VDD_3V3_LOGIC
IPU2_CSI1 vertical sync
A40
X_CSI1_HSYNC
I
VDD_3V3_LOGIC
IPU2_CSI1 horizontal sync
A41
GND
-
-
Ground 0 V
A42
X_EIM_BCLK
O
VDD_3V3_LOGIC
EIM burst block
A43
X_ECSPI2_MISO I/O
VDD_3V3_LOGIC
eCSPI2 master input/slave output
A44
X_ECSPI2_SS1
I/O
VDD_3V3_LOGIC
eCSPI2 chip select 1
A45
X_ECSPI2_SS0
I/O
VDD_3V3_LOGIC
eCSPI2 chip select 0
A46
GND
-
-
Ground 0 V
A47
X_LCD_DATA22
O
VDD_3V3_LOGIC
DISP0 data 22
A48
X_LCD_DATA21
O
VDD_3V3_LOGIC
DISP0 data 21
A49
X_LCD_DATA19
O
VDD_3V3_LOGIC
DISP0 data 19
A50
X_LCD_DATA16
O
VDD_3V3_LOGIC
DISP0 data 16
A51
GND
-
-
Ground 0 V
A52
X_LCD_DATA14
O
VDD_3V3_LOGIC
DISP0 data 14
A53
X_LCD_DATA13
O
VDD_3V3_LOGIC
DISP0 data 13
A54
X_LCD_DATA11
O
VDD_3V3_LOGIC
DISP0 data 11
A55
X_LCD_DATA08
O
VDD_3V3_LOGIC
DISP0 data 8
A56
GND
-
-
Ground 0 V
A57
X_LCD_DATA06
O
VDD_3V3_LOGIC
DISP0 data 6
A58
X_LCD_DATA05
O
VDD_3V3_LOGIC
DISP0 data 5
A59
X_LCD_DATA03
O
VDD_3V3_LOGIC
DISP0 data 3
A60
X_LCD_DATA00
O
VDD_3V3_LOGIC
DISP0 data 0
A61
GND
-
-
Ground 0 V
A62
X_LCD_ENABLE O
VDD_3V3_LOGIC
DISP0
enable
A63
X_LCD_HSYNC
O
VDD_3V3_LOGIC
DISP0 horizontal sync
A64
X_LCD_RESET O
VDD_3V3_LOGIC
DISP0
reset
A65
X_ENET_REFCLK
I
VDD_3V3_LOGIC
ENET RMII reference clock
A66
GND
-
-
Ground 0 V
A67
X_ENET_TXER O
VDD_3V3_LOGIC
ENET
transmit
error
A68
X_ENET_RXD0
I
VDD_ENET_IO
ENET RMII receive data 0
A69
X_ENET_RXD1
I
VDD_ENET_IO
ENET RMII receive data 1
A70
X_ENET_RX_ER
I
VDD_ENET_IO
ENET RMII receive error
Table 3:
Pinout of the phyCORE-Connector X1, Row A (continued)
Summary of Contents for phyCORE-i.MX 6
Page 14: ...phyCORE i MX 6 PCM 058 xii PHYTEC Messtechnik GmbH 2016 L 808e_2...
Page 33: ...Jumpers PHYTEC Messtechnik GmbH 2016 L 808e_2 19 Figure 6 Jumper Locations top view J6 J3 J4...
Page 78: ...phyCORE i MX 6 PCM 058 64 PHYTEC Messtechnik GmbH 2016 L 808e_2...
Page 82: ...Published by PHYTEC Messtechnik GmbH 2016 Ordering No L 808e_2 Printed in Germany...