Programming
Page
D-138
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw Notes
1 : TRUE
128.05 SERIAL
NUMBER
CONTROLNET
INT
_
0
ro Output
128.06
FAULT
CONTROLNET
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
128.07
DIAGNOSTIC
CONTROLNET
WORD
0000 to FFFF
0000
ro
Output
128.08
FIXED PARAM SET
CONTROLNET
ENUM
0 : NONE
NONE
rw
2
128.09
CNET STATE
CONTROLNET
ENUM
0 : NONE
1 : FAULT
2 : INITIALISE
3 : VM CONFIGURE
4 : WAIT 2 ATTACH
5 : WAIT 2 CONNECT
6 : RUNNING
NONE ro
Output
129.01
MODE
COMMS PORT
ENUM
0 : AUTOMATIC
1 : 6511 OP STATION
2 : 6901 OP STATION
3 : TS8000 HMI
AUTOMATIC rw
130.01
BAUDRATE(SWITCH)
DEVICENET
ENUM
0 : 125K
1 : 250K
2 : 500K
3 : 125K
125K ro
Output
130.02 ADDRESS
(SWITCH) DEVICENET
INT
_
63
ro Output
130.03
CONNECTION STATE
DEVICENET
ENUM
0 : NON_EXISTENT
1 : SELFTEST
2 : STANDBY
3 : OPERATIONAL
4 : RECOVER FAULT
5 : UNRECOVER FAULT
NON_EXISTENT ro
Output
130.04
DEVICE STATUS
DEVICENET
ENUM
0 : NO ERROR
1 : OWNED
2 : CONFIGURED
3 : MINOR REC FAULT
4 : MINOR UNREC FLT
5 : MAJOR REC FAULT
6 : MAJOR UNREC FLT
NO ERROR
ro
Output
130.05
HARDWARE(SWITCH) DEVICENET
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output