The Keypad
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
8-33
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Keys for Operating the Drive Locally
FORWARD/
REVERSE
Control
- Changes the direction of motor rotation. Only operates when the drive
is in Local Speed Control mode.
JOG
JOG
Control
- Runs the motor at a speed determined by the JOG SETPOINT
parameter. When the key is released, the drive returns to “stopped”. Only
operates when the drive is “stopped“ and in Local Start/Stop mode.
RUN
Control
- Runs the motor at a speed determined by the LOCAL SETPOINT or
REMOTE SETPOINT parameter.
Trip Reset
- Resets any trips and then runs the motor as above. Only operates
when the drive is in Local Start/Stop (Seq) mode.
STOP/RESET
Control
- Stops the motor. Only operates when the drive is in Local Sequence
mode.
Trip Reset
- Resets any trips and clears displayed message if trip is no longer
active.