![Parker 890CS Product Manual Download Page 440](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717440.webp)
Technical Specifications
Page
E-4
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
Model Number
Block Variable Description
3 cont. XXXX
Current Rating (Continuous Input RMS Amps)
Common Bus Supplies (CS):
230 thru 500 Vac Units:
0032B = 25 HP@460Vac/15kW@400Vac: Frame B
0054B = 45 HP@460Vac/30kW@400Vac: Frame B
0108D = 75 HP@460Vac/60kW@400Vac: Frame D
0162D = 135 HP@460Vac/90kW@400Vac: Frame D
(Note: For 230Vac Power Ratings divide by 2)
Current Rating (Continuous DC Bus in Amps)
Common Bus Adaptor (CA):
0050B = 50 Amp DC with additional bus caps: Frame B
0080B = 80 Amp DC no additional bus caps: Frame B
4 X One
character
specifying
the Dynamic Braking Option:
N = No Braking Control:
CD Units Frames B, C and D
(Brake Switch is not available)
B = Braking Control:
Standard on CS/SD frames B, C and D
(external resistor(s) required for full rated braking. SD Frame B includes
internal limited duty cycle braking resistors, jumper selectable)
5 XX Two
characters
specifiying the build option:
00 = Not applicable
RT = Ride Through Capacitors (890CA, 50A rating only)