![Parker 890CS Product Manual Download Page 423](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717423.webp)
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
D-139
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw Notes
130.06
BAUDRATE(SOFT)
DEVICENET
ENUM
0 : 125K
1 : 250K
2 : 500K
125K rw
130.07
ADDRESS (SOFT)
DEVICENET
INT
1 to 63
1
rw
131.01
INHIBIT
TRACKING TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE rw
131.02
THRESHOLD
TRACKING TRIP
INT
0 to 2147483647
65536
rw
131.03
DELAY
TRACKING TRIP
REAL
0.00 to 10.00 s
0.00 s
rw
131.04
TRIPPED
TRACKING TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
132.01
INHIBIT
LOOP OVER SPEED TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE rw
132.02
THRESHOLD
LOOP OVER SPEED TRIP
REAL
0.00 to 150.00 %
110.00 %
rw
132.03
DELAY
LOOP OVER SPEED TRIP
REAL
0.00 to 10.00 s
0.00 s
rw
132.04
TRIPPED
LOOP OVER SPEED TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
133.01
NAME
RESOLVER
STRING
max length is 16 chars
rw
133.02
POLES
RESOLVER
INT
2 to 20
2
rw
133.03
RATIO
RESOLVER
REAL
0.20 to 1.00
0.50
rw
133.04
SPEED MAX
RESOLVER
INT
0 to 2147483647
10000
rw
133.05
ACCURACY
RESOLVER
REAL
0.00 to 60.00
20.00
rw
133.06
CARRIER VOLTAGE
RESOLVER
REAL
5.00 to 10.00 V
7.00
rw
133.07
CURRENT
RESOLVER
REAL
0.000 to 1.000 A
0.046
rw
133.08
INERTIA
RESOLVER
REAL
10.00 to 32768.00Kg.cm2
24.00
rw
133.11
POSITION SET UP
RESOLVER
REAL
-180.00 to 180.00 deg
0.00
rw
133.15 RESOLVER
POS
OUT RESOLVER
REAL
_.xxxx
ro Output
133.16
TRIP
RESOLVER
BOOL
0 : FALSE
1 : TRUE
FALSE ro
Output
133.17
INIT DONE
RESOLVER
BOOL
0 : FALSE
1 : TRUE
TRUE ro
Output
133.18
REVERSE CNT DIR
RESOLVER
BOOL
0 : FALSE
1 : TRUE
FALSE rw
133.19
SPEED FILTER
RESOLVER
REAL
10.00 to 1000.00 Hz
100.00
rw
133.20
PHASE SHIFT
RESOLVER
REAL
0.00 to 180.00 deg
0.00
rw