Parameter Descriptions
MAX VOLTAGE
PREF: 134.05
Default: 400.00
Range: 200.00 to 640.00 V
Set the motor’s maximum ac input voltage (in Volts rms).
THERM PROTECTION
PREF: 134.06
Default: FALSE
Range: FALSE / TRUE
Motor’s thermal protection feature.
MAX SPEED
PREF: 134.07
Default: 4300
Range: 0 to INT MAX
Set the motor’s maximum mechanical speed (in rpm)
MAX CURRENT
PREF: 134.08
Default: 10.60
Range: 0.00 to 1024.00 A
Set the motor’s maximum rms current .
PERM CURRENT
PREF: 134.09
Default: 4.90
Range: 0.00 to 1024.00 A
Set the motor’s permanent rms current.
PERM TORQUE
PREF: 134.10
Default: 6.40
Range: 0.00 to 10000.00 Nm
Set the motor’s permanent torque.
LOW SPEED VALUE
PREF: 134.11
Default: 0
Range: 0 to INT MAX rpm
Set the motor’s low speed value (in rpm) below which the current must be reduced.
If this parameter is unknown, value must be set to 0 rpm.
POLES
PREF: 134.12
Default: 10
Range: 0 to 400
Set the number of motor poles, e.g. for a 4 pole motor enter "4".
BACK EMF
PREF: 134.13
Default: 85.6
Range: 0.0 to 8192.0 V
Set the motor’s Back EMF phase to phase, rms value (in Volts/1000rpm).