![Parker 890CS Product Manual Download Page 211](http://html2.mh-extra.com/html/parker/890cs/890cs_product-manual_3748717211.webp)
Keypad Menus
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
9-25
8
9
10
11
A
B
C
D
1
2
3
4
5
6
7
E
QUICK SETUP MENU
890CD Common Bus Drive & 890SD Standalone Drive
PREF
6511/6901
Display
Description
Range
Default
27.04
*
MOTOR
VOLTAGE
This parameter contains the motor nameplate
voltage at base frequency
0.0 to 575.0V
product
code
dependent
27.07
*
NAMEPLATE RPM
This parameter contains the motor nameplate
full-load rated speed. This is the motor speed
in rpm at base frequency minus full load slip
0.0 to 30000.0 RPM
product
code
dependent
27.09
MOTOR POLES
This parameter contains the number of motor
poles, as supplied on the motor nameplate
0=2 pole
1=4 pole
2=6 pole
3=8 pole
4=10 pole
5=12 pole
1
27.08
*
MOTOR
CONNECTION
This parameter contains the motor nameplate
connection.
0= DELTA
1= STAR
1
71.01
PULSE ENC VOLTS
The voltage output from the encoder feedback
card.
10 to 20V
5.0
71.02
ENCODER LINES
The number of lines must be set to match the
type of encoder being used. Incorrect setting
of this parameter will result in an erroneous
speed measurement.
250 to 32767
2048