Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames B, C & D
Page
D-137
8
9
10
A
B
C
D
E
1
2
3
4
5
6
7
PREF
Name
Block
Type
Range
Default
ro\rw Notes
126.07
ADDRESS SOFT
CANOPEN
INT
1 to 127
1
rw
127.01
BAUDRATE
PROFIBUS
ENUM
0 : 12 Mbits/sec
1 : 6 Mbits/sec
2 : 3 Mbits/sec
3 : 1.5 Mbits/sec
4 : 500 kbits/sec
5 : 187.5 kbits/sec
6 : 93.75 kbits/sec
7 : 45.45 kbits/sec
8 : 19.2 kbits/sec
9 : 9.6 kbits/sec
10 : UNKNOWN
UNKNOWN ro
Output
127.02 ADDRESS
PROFIBUS
INT
_
0
ro Output
127.03
STATUS
PROFIBUS
ENUM
0 : MISSING OR FAULT
1 : DISABLED
2 : BAUD SEARCH
3 : WAIT PARAM
4 : WAIT CONFIG
5 : DATA EXCHANGE
6 : DATA EXCH NO WD
7 : DATA EXCH ERROR
8 : DATA EX ER NO WD
MISSING OR
FAULT
ro Output
127.04
ADDRESS METHOD
PROFIBUS
ENUM
0 : SOFTWARE
1 : HARDWARE
HARDWARE ro
Output
128.01 NODE
ADDRESS
CONTROLNET
INT
_
0
ro Output
128.02
ADDRESS METHOD
CONTROLNET
ENUM
0 : HARDWARE
1 : SOFTWARE
HARDWARE ro
Output
128.03
NETWORK MODE
CONTROLNET
ENUM
0 : INVALID
1 : POWER UP
2 : CHECK FOR CABLE
3 : WAITING 2 ROGUE
4 : CHK 4 MODERATOR
5 : I'M ALIVE
6 : ATTACHED
7 : FORCED LISTEN
8 : DUPLICATE NODE
INVALID ro
Output
128.04
CONNECTED
CONTROLNET
BOOL
0 : FALSE
FALSE
ro
Output