5-2
5-2. Hold and restart
Never enter into the safety fenced area. The robot may move suddenly
where it is in HOLD state.
Warning
Make sure that no personnel or any articles to interfere with the robot are
present within the robot work envelope prior to restarting the robot.
1. Press
the
Hold
switch, then the robot becomes inactive while keeping the servo power ON.
2. Place the mode select switch in the TEACH position to operate the robot arm manually.
3. Switch the mode select switch to AUTO and press the Start switch to restart the robot.
Teaching
Operation
Hold
Manual
Restart
Robot resumes operation from the position the
robot has been manually moved to in the Hold
state.
Input/Output
states
before the robot goes
in the hold state are retained until the robot
is restarted.
5-3. Emergency stop and restart
Warning
Bring the robot to an emergency stop immediately when you observe
hazardous or an abnormal condition.
Make sure that no personnel or any articles to interfere with the robot are
present within the robot work envelope prior to restarting the robot.
1. Press the Emergency stop switch to bring the robot to an emergency stop.
2. Remove the cause, and then turn on the servo-ON and then start switch to restart.
Input/Output states before the robot goes in the emergency stop are retained when the servo power is newly
turned ON.
5-4. Limit condition of operation
You can run the specified program adding some limitation(s), such as deactivating some function(s), limit the robot travel
speed or execute the operation without welding (check the Arc lock).
Click
>>
Limit
condition
Î
[Speed]
The speed specified in this box has priority over the
max. speed set in teaching operation.
[I/O lock]
Deactivates I/O related sequence commands.
[Arc lock]
Deactivates welding related commands.
[Robot lock]
Deactivates robot motion.