15-17
15-3-3. Adjust value
It specifies the differences between the actual values of welding current and pulse frequency and their set values as the
adjustment value respectively.
Adjust value
Î
[Current]:
Adjustment value of current. [-50 to +50]
[FRQ]:
Adjustment value of frequency [-5.0 to +5.0]
15-3-4. High frequency and arc start process
It specifies whether to apply high frequency oscillation and polarity of start pulse.
High FRQ
Arc start
process
For standard TIG welding power source.
For models for selectable EP and EN start. (YC-300BP2)
15-3-5. Pulse settings
It specifies whether to apply pulse, and pulse width to be applied.
Set pulse
mode
Î
[Pulse]:
Specifies whether to use this function (
Valid
) or
not (
Invalid
).
[Pulse width]:
Pulse width in percentage. [5 to 95]
15-3-6. Wire control
It specifies whether to use filler wire, and conditions to be applied.
Wire control
Î
[Filer wire]:
Specifies whether to use the filer wire.
[TIG I/F board ID]:
Specifies ID to set DIP switches for
the filler wire control card.
[Speed definition]:
Specifies wire speed set method.
[Correct] button:
Click to display the “Wire speed
adjust” dialog box
[Charact.] button:
Click to display the “Wire spd
Character” dialog box.
For details of other items, please refer to section “Welder data settings for CO2/MAG/MIG welding.”