16-23
16-5-38. WFED
Format
WFED [Feed rate]
Function
It sets wire feed rate.
Feed rate
Condition
Weld package
Wire feed rate.
[0.00 - 15.00] m/min
Lock condition
Arc lock (Internal execution)
Syntax check
None
Example
Set wire feed rate to 10 m/min.
WFED 10.00
The same command in
conventional models
WFED
16-5-39. WIREFWD
Format
WIREFWD [ON/OFF]
Function
It starts or terminates wire forward
feed.
ON/OFF
ON: to feed wire.
OFF: to terminate wire feed.
Condition
Weld package
*
Lock condition
Arc lock
Syntax check
None
Prior to this command, it is necessary to
insert the “AMP=” command that specifies
wire speed.
Example
Feeds wire forward.
WIREFWD ON
The same command in
conventional models
OUTB OPORT#212=*
16-5-40. WIRERWD
Format
WIRERWD [ON/OFF]
Function
It starts or terminates wire retraction.
ON/OFF
ON: to start wire retraction.
Condition
Weld package
OFF: to terminate wire retraction.
Lock condition
Arc lock
*
Syntax check
None
Prior to this command, it is necessary to
insert the “AMP=” command that specifies
wire speed.
Example
Retracts wire
WIRERWD ON
The same command in
conventional models
OUTB OPORT#213=*
DELAY 0.1
OUTB OPORT#212=*
16-5-41. WIRSLDN
Format
WIRSLDN [Value]
Value
Fine adjustment value which will
be added to the system set value.
[-125 - +125]
Function
It adjusts the wire slow-down speed.
Increase the value to shorten the time to
generate an arc.
Decrease it for better arc start.
*
Condition
Weld package
Exe1 adjustment twice
does not result in +2.
Lock condition
Arc lock (Internal execution)
Syntax check
None
Example
Adjust the system set value by +1.
WIRSLDN +1
The same command in
conventional models
WIRESLDN