11-8
11-4. Speed limit settings
11-4-1. Manual/Override speed limit
It specifies the maximum robot travel speed in manual operation. It also specifies the override speed limit in AUTO mode
separate from the speed in teaching operation.
This function is useful in a system the reference speed is set to the external axis. As in such system the robot motion
speed is likely set above the override upper speed limit. Therefore, by setting the override speed limit separately with
this function, it can avoid possible termination of welding operation when the override is turned ON.
Click
>>
Set
>>
Controller
>>
Speed limit
>>
TCP
Speed limit
Î
[Manual /Override speed limit]
Specifies the maximum speed in manual operation.
Set range: (0-12.5 %) or (0-15.00 m/min)
*
[Set the limit for override separately]
Set range: (0.1-100.0 %) or (0.01-120.00 m/min)
* For handling robots:
This setting is not effective.
Limit speed set range varies with parts number of the robot controller and the robot manipulator.
11-4-2. Joint speed limit
It specifies the maximum travel speed for each joint axis. Specify a percentage to the rated motor speed.
Click
>>
Set
>>
Controller
>>
Speed limit
>>
Joint
Speed limit
Î
[Speed limit]
Specifies percentage to the rated motor
speed.
[Re-trace speed]
Specifies the speed limit at re-trace
after the robot makes a warning hold.
[Trace limited]
Specifies the validity of the function in
trace operation.
[Warning hold]
Select “Valid” to make a warning hold
when the travel speed exceeds the preset speed limit.
Select “Invalid” to continue robot operation at the speed
limit when the travel speed exceeds the preset speed
limit.
[Default]
Resets the settings in this dialog box to the
factory settings at shipment.