16-39
16-11-3. TOOL
Format
TOOL [Tool No.]
Function
It switches tools.
Tool No.
Applied tool No. and tool name.
Condition
Standard.
Lock condition
None.
Syntax check
None.
Example
Change tool to [1:STD].
TOOL 1:STD
The same command in
conventional models
TOOL
16-12. Shift commands
16-12-1. SHIFT-OFF
Format
SHIFT-OFF
Function
It terminates coordinate system shift
Condition
Standard.
Lock condition
None.
Syntax check
None.
Example
To reset shift.
SHIFT-OFF
16-12-2. SHIFT-ON
Format
SNSSFT-ON [Coordinate systems] = [Variable]
Function
It starts coordinate system shift
Condition
Standard.
Coordinate
systems
A coordinate system to be
shifted.
Lock condition
None.
Variable
Shift amount. (GD, GT)
Syntax check
None.
Example
Shift the operation onwards on the robot coordinate system by GD001.
SHIFT-ON ROBOT = GD001
16-13. Touch Sensor commands (Optional)
16-13-1. SNSSFTLD
Format
SNSSFTLD [Variable]
Function
It assigns the value of specified variable as the
sensor shift amount.
Variable
Shift amount. (GD)
Condition
Standard.
Lock condition
None.
Syntax check
Error if variable types do not match.
Example
Assign GD001 as sensor shift amount.
SNSSFTGD GD001
The same command in
conventional models
LDBUF