16-40
16-13-2. SNSSFT-OFF
Format
SNSSFT-OFF
Function
It terminates sensor shift
Condition
Standard.
Lock condition
None.
Syntax check
None.
Example
Terminate sensor shift.
SNSSFT-OFF
The same command in
conventional models
SFTBUF=0
16-13-3. SNSSFT-ON
Format
SNSSFT-ON
Function
It starts sensor shift
Condition
Standard.
Lock condition
None.
Syntax check
None.
Example
Start sensor shift.
SNSSFT-ON
The same command in
conventional models
SFTBUF=1
16-13-4. SNSSFTRST
Format
SNSSFTRST
Function
It clears the sensor shift amount.
Condition
Standard.
Lock condition
None.
Syntax check
None.
Example
Reset sensor shift amount.
SNSSFTRST
16-13-5. SNSSFTSV
Format
SNSSFTSV [Variable]
Function
It stores the current sensor shift amount to the
specified variable.
Variable
Shift amount (GD)
Condition
Standard.
Lock condition
None.
Syntax check
Error if variable types do not match.
Example
Store the sensor shift to GD001.
SNSSFTSV GD001
The same command in
conventional models
RSTBUF
16-13-6. TCHSNS
Format
TCHSNS SPD= [Speed]
Function
It starts touch sensing
Speed
Sensing speed in m/min.
Condition
Standard.
Lock condition
None.
Syntax check
None.
Example
Start touch sensing at speed 0.5 m/min.
TCHSNS SPD=0.5
The same command in
conventional models
TCHSNS
Note
The result of the touch sensing (shift amount) is stored in the sensor shift amount.