16-27
16-7-5. CRATER_TIG
Format
CRATER_TIG Ib=[Base Amp] Ip=[Peak Amp] WF=[Filler spd] FRQ=[Frequency] T=[Timer]
Function
It sets crater welding conditions for TIG welding.
Base Amp
Base amperage. [1 – 999] A
Condition
Weld package.
Peak Amp
Peak amperage. [1 – 999] A
Lock condition
Arc lock (Internal execution, set values).
Filler spd
Filler speed. [0.00 - 99.99]
Syntax check
None.
Frequency
Frequency. [0.0 - 500.0] Hz
Example
Speed
Welding speed. [0.00 - 99.99]
m/min
Set parameters for TIG welding operation whose
base current is 100A, peak current is 120 A, filler
speed is 10 and frequency is 1.0 Hz for 0.2
seconds.
CRATER_TIG Ib=100 Ip=120 WF=10 FRQ
=
1.0 T=0.2
The same command in
conventional models
CJO(TIG)
16-7-6. IB_TIG
Format
IB_TIG [Base amperage]
Function
It sets base amperage for TIG welding.
Amperage [0 - 999] A.
Condition
Weld package.
Base
amperage
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Set the base amperage to 100 A.
IB_TIG = 100
The same command in
conventional models
IB
16-7-7. IP_TIG
Format
IP_TIG [Peak amperage]
Function
It sets peak amperage for TIG welding.
Amperage [0 to 999] A.
Condition
Weld package.
Peak
amperage
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Set peak current to 150 A.
IP_TIG = 150
The same command in
conventional models
IP
16-7-8. MIXFRQ
Format
MIXFRQ = [Frequency]
Function
It sets MIX-TIG frequency.
Frequency
Frequency [0.5 - 10.0] Hz
Condition
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Set the MIX-TIG frequency to 1.0Hz.
MIXFRQ = 1.0
The same command in
conventional models
16-7-9. MIXRATE
Format
MIXRATE = [Value]
Function
It sets the AC ratio of MIX-TIG welding.
Value
AC ratio [10 – 90]
%
Condition
Lock condition
Arc lock (Internal execution).
Syntax check
None.
Example
Set the AC ratio to 50%.
MIXRATE = 50
The same command in
conventional models