15-2-7. Arc retry
It is a function to be used if the welding machine failed to generate an arc at arc start. The robot automatically shifts its
position to retry arc start action.
Arc retry
Î
[Re-start]
Specifies whether to use this function (Valid)
or not (Invalid).
[Arc detect time]
Specifies how much time (in seconds)
the robot will wait before retrying the arc start after the
arc start error occurs. (Set range: 0.1 to 9.9 sec)
[Retry count]
Specifies how many times (1 to 9) the
robot will retry the arc start action.
[Jog]
Specifies the distance the robot will shift the arc
start position in the direction of the welding line during
each arc retry. (Set range: 0.0 to 9.9 mm)
[Return speed]
Specifies the speed when the robot
returns to the original arc start point after the arc retry.
(Set range: 0.1 to 9/9 m/min)
[Retract time]
Specifies the wire retract amount time
when the arc start error occurs. (Set range: 0.1 to 9.9 s)
15-2-8. Stick release
It is a function that the robot automatically uses to cut the wire at the arc end in case of a wire stick.
Stick
release
Î
[Re-start]
Specifies whether to use this function (
Valid
)
or not (
Invalid
).
[Current]
Specifies the wire fusing current.
(Set range: 1 to350 A)
[Voltage]
Specifies the wire fusing voltage.
(Set range: 1 to 50V)
[Weld time (T1)]
Specify the wire fusing time.
(Set range: 0.0 to 9.9 s)
[Wait un-stick (T2)]
Specifies how much time the robot
will wait before starting the wire stick check.
(Set range: 0.1 to 9.9 s)
[Retract wire]
Specifies whether to retract the wire
(Valid) or not (Invalid) before the stick check.
15-2-9. Wire auto retract
<This function is availble only to built-in welding power source type robot controllers.>
To use the “Wire auto retract”, specify the stick release number 6 or 7 in the Arc-OFF command. Then the wire will be
automatically rewound the wire automatically to shorten the wire extension to proper length after the completion of welding
operation. Therefore, the wire can easily get ready at the next arc start point.
Stick
release
[Stick release]
: Specifies a stick release condition (0-5)
Wire rewind condition:
[Current]
: Coefficient of motor revolution (0-999) A
[Time]
: Motor retraction time (0.01
〜
2.00) s