16-9. Weld commands
(
MIG
、
TIG-FORCE application
)
16-9-1. ARC-SET_TIGFC
Format
ARC-SET_TIGFC Ib=[Base Amp] Ip=[Peak Amp] WFb=[Base WFS] WFp=[Peak WFS]
FRQ=[Frequency] S=[Speed]
Function
It specifies welding conditions for TIG Force.
Base Amp
Base amperage: [1-999] A
Condition
Using TIG-FORCE.
Peak Amp
Peak amperage: [1-999] A
Lock condition
Arc lock (Internal execution)
Base WFS
Min. wire speed: [0.10-30.00] m/min
Syntax check
None.
Peak WFS
Max. wire speed: [0.10-30.00] m/min
Frequency
Frequency: [0.0-500.0] Hz
Speed
Welding speed: [0.01-120.00] m/min
Example
Perform TIG welding with base amp at 120A, peak amp. At 180A, base wire feed speed at 1 m/min, peak
wire feed speed at 12 m/min and frequency at 0.5 Hz at the speed of 0.5 m/min.
ARC-SET_TIGFC Ib=120 Ip=180 WFb=1 WFp=12 FRQ=0.5 S=0.50
16-9-2. CRATER_TIGFC
Format
CRATER_TIGFC Ib=[Base Amp] Ip=[Peak Amp] WFb=[Base WFS] WFp=[Peak WFS]
FRQ=[Frequency] T=[Time]
Function
It specifies crater conditions for TIG Force.
Base Amp
Base amperage: [1-999] A
Condition
Using TIG-FORCE.
Peak Amp
Peak amperage: [1-999] A
Lock condition
Arc lock (Internal execution)
Base WFS
Min. wire speed: [0.10-30.00] m/min
Syntax check
None.
Peak WFS
Max. wire speed: [0.10-30.00] m/min
Frequency
Frequency: [0.0-500.0] Hz
Time
Crater time: [0.00-99.99] s
Example
Perform crater welding with base amp at 120A, peak amp. At 180A, base wire feed speed at 12 m/min,
peak wire feed speed at 1 m/min and frequency at 0.5 Hz for 0.2 second.
ARC-SET_TIGFC Ib=120 Ip=180 WFb=1 WFp=12 FRQ=0.5 S=0.50
16-9-3. LOAD TIGFC
Format
LOAD TIGFC
Function
It loads the temporarily stored welding conditions
for TIG Force.
Condition
Using TIG-FORCE.
Lock condition
Arc lock (Internal execution)
Syntax check
None.
Example
LOAD TIGFC
16-9-4. SAVE TIGFC
Format
SAVE TIGFC
Function
It temporarily stores welding conditions for TIG
Force in buffer.
Condition
Using TIG-FORCE.
Lock condition
Arc lock (Internal execution)
Syntax check
None.
Example
SAVE TIGFC