80
No.
Name and description
w
Count-up value correction (SELECT 1 IN: ON)
e
Count-down value correction (SELECT 0 IN, SELECT 1 IN: ON)
Input this number when you change the next marking value of the counter function. The counter value
is specified by the step times of count-up or count-down. The step value indicates a value to increase or
decrease per one counting-up or counting-down.
Specify the count-up/count-down with SELECT 0 IN to SELECT 2 IN.
Specify the target counter number and step times as D0 to D15 and turn ON SET IN (No.2).
• How to select the counter number:
Select a value from D0 to D7 for the counter number to correct the count-up/count-down value.
The counter No. 0 to 3 is assigned at D0 to D3 and the common counter No. 16 to 19 is assigned at D4
to D7 respectively.
In case two or more counter numbers are specified, counter values of all the specified counter numbers
are changed.
• How to specify the step times:
Specify a value in D8 to D15 for the step times of count-up or count-down in the binary system. Indicate
values in the binary system as ON/OFF of D8 to D15 with D8 being the lowest digit value.
Example: Count up or count down the counter of the counter number 3 by two steps
• Turn ON D3 which represents the counter number 3.
• Select “0000 0010”, which represents the step times 2 in a 8-bit binary system, by specifying ON/OFF
of D8 to D15 as shown in the below table.
D0 to D7: Counter No. 0 to 3, 16 to 19
Terminal
Counter No.
Input
D0
0
OFF
D1
1
OFF
D2
2
OFF
D3
3
ON
D4
16
OFF
D5
17
OFF
D6
18
OFF
D7
19
OFF
D8 to D15: Step times
Terminal
Step times (binary)
Input
D8
0
OFF
D9
1
ON
D10
0
OFF
D11
0
OFF
D12
0
OFF
D13
0
OFF
D14
0
OFF
D15
0
OFF
Counter No. 16 to 19 are the common counters you can use with all the files.
r
Counter No. to reset (SELECT 2 IN: ON)
Input this number when you restore the present counter value to the initial value for files with the counter
function applied.
Specify the target counter number as D0 to D15 and turn ON SET IN (No.2).
• How to select the counter number:
Select the counter number to reset from D0 to D15.
The following counter numbers are assigned to D0 to D15 respectively.
D0 to D3: Counter No. 0 to 3
D4 to D7: Common Counter No. 16 to 19
D8 to D11: Counter No. 4 to 7
D12 to D15: Common Counter No. 20 to 23
In case two or more counter numbers are specified, all counters specified are reset.
Example: When the counter No. 0 to 3 are reset.
Turn ON D0, D1, D2, and D3 which represent the counter No. 0, 1, 2, and 3.
D0 to D7: Counter No. 0 to 3, 16 to 19
Terminal
Counter No.
Input
D0
0
ON
D1
1
ON
D2
2
ON
D3
3
ON
D4
16
OFF
D5
17
OFF
D6
18
OFF
D7
19
OFF
D8 to D15: Counter No. 4 to 7, 20 to 23
Terminal
Counter No.
Input
D8
4
OFF
D9
5
OFF
D10
6
OFF
D11
7
OFF
D12
20
OFF
D13
21
OFF
D14
22
OFF
D15
23
OFF
Counter Nos. 16 to 23 are the common counters you can use with all the files.
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...