130
6-1-9 Timing chart
Position correction - Marking (when TIMING IN signal is used)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
T1
T1
T6
T2
T3
T5
T4
TRIGGER IN (X5)
PROCESSING OUT (Y10)
PROCESSING END OUT (Y11)
SCRIPTING OUT (No.37)
TIMING IN (No.24)
TIMING WAIT OUT (No.36)
READY OUT (Y5)
Starting location detection signal
Marking trigger
LASING OUT (Y20)
Item
Time
Remarks
T1
2ms or more
Keep the ON status for 2ms or more.
T2
―
Processing time of linkage operations with the image checker.
In this case, it is the following time.
• Time for location detection by image checker
• Time for marking position correction by the laser marker
T3
―
When TRIGGER IN (X5) is accepted, PROCESSING OUT (Y10) turns ON.
The output time of PROCESSING OUT includes the trigger delay time, operation time,
laser radiation time and laser marker internal processing time of the linkage devices.
T4
Max. 60 sec
Turn on TIMING IN within 60 seconds after TIMING WAIT OUT is turned ON.
If there is no input of TIMING IN within 60 seconds, an error occurs and trigger processing
is terminated due to the abnormality.
T5
―
Laser radiation time. This varies depending on marking contents.
T6
2 to 510 ms
One-shot output. Set the output time on the system settings screen.
There is a small margin of error for the setting value.
ME-LPGS-SM-8
Summary of Contents for LP-GS Series
Page 17: ...1 Product Overview ME LPGS SM 8 ...
Page 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Page 48: ...3 Operation Method ME LPGS SM 8 ...
Page 68: ...4 External Control Using I O ME LPGS SM 8 ...
Page 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Page 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Page 141: ...7 Maintenance ME LPGS SM 8 ...
Page 161: ...161 MEMO ME LPGS SM 8 ...
Page 162: ...Troubleshooting ME LPGS SM 8 ...
Page 186: ...Index ME LPGS SM 8 ...
Page 189: ......
Page 190: ... Panasonic Industrial Devices SUNX Co Ltd 2014 2019 April 2019 ...