61
2-1-2 Installation of LP-400 Series Head
WARNING
•
Install the product so that the laser beam path does not cross the eye height.
•
The laser beam path shall be enclosed with protective enclosure and make sure
it is not exposed with direct light or reflected light.
⿎
Installation Method
•
Install the head on a plate with a thickness of 10 mm to 15 mm which is made of aluminum or other material with
radiation performance equivalent to that of aluminum.
•
For the installation dimension, refer to the outer dimension in “1-4-1 LP-400 Series” (P.40).
•
Fix the head with the following conditions.
Head type
Fixing position
Fixing screw
Inserting length of the screw
Tightening torque
Standard head
Bottom face
M6 screws at 6
positions
7 mm to 10 mm
3.0N
・
m or below
Tower head
Rear face
7 mm to 10 mm
Bottom face
(Laser emission port side)
5 mm to 7 mm
Laser marker
Washer thi stand thick
Inserting length of the screw (See above table for the length.)
M6 screw
120
180
180
182
150
90
55
180
130
180
200
113
87
Standard Head Model
Tower Head Model
Notice
•
Check the length of the screw and install it. Using improper screws and forcibly tightening them might damage the
product.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...