165
Description
3
Init / End (Initial Value / End Value):
The initial value and the end value of the counter. When the counter value reaches to the end value, the marking is
started from initial value again.
When the initial value is smaller than the end value: Counting up
When the initial value is larger than the end value: Counting down
Setting Range
0 to 999999
Reference
•
Set the different value to the initial and the end value. If the same value is set to both, the counter value does not
change.
4
Step (Step Value):
Sets the value to be changed per count.
Setting Range
0 to 999999
5
Source (Count Source) :
Target for timing of counting up and counting down. The count-up or count-down is started at the timing of count
source end. The count source can be switched by pressing button.
Setting Range
TRIG (Trigger)
Counts up or counts down by trigger input.
Counter 0
Counts up or counts down when counter 0, 1, 2 or 3 ends.
Counter 1
Counter 2
Counter 3
Counter 4
Counts up or counts down when common counter 4, 5, 6 or 7 ends.
Counter 5
Counter 6
Counter 7
6
Reset at Data Update:
With checking on this function, the counter value is reset at the internal clock becomes “0:00”.
Reference
•
When the date changes during the Time Hold function is effective, the counter value is reset at the timing of releasing
Time Hold (the time hold input is OFF).
• The counter reset at update cannot apply to the marking to flying object.
7
RESET:
Returns current value to initial value by pressing [RESET].
Setting Example : When marking the same value in series
In case of marking the character like 000
u
000
u
000
u
002
u
002
u
002
u
004
u
...
000
u
000
u
000
u
002
u
002
u
002
u
004
...
Character Setting
Function Setting Counter
01:% 03:CO
02:
03:
Counter 0: Initial=0, End=998, Step 2, Count Source=Counter 1
Counter 1: Initial=1, End=3, Step 1, Count Source=Trigger
It is not specify character string for marking to Counter 1.
ME-LP400V-OP-6
Summary of Contents for LP-400 Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...